SearcharxivSearch

arXiv · 1704.08706

High Spatial-Resolution Fast Neutron Detectors for Imaging and Spectrometry

Abstract

Two detection systems based on optical readout were developed: a. Integrative optical detector A 2nd generation of Time-Resolved Integrative Optical Neutron (TRION) detector was developed. It is based on an integrative optical technique, which permits fast-neutron energy-resolved imaging via time-gated optical readout. This mode of operation allows loss-free operation at very high neutron-flux intensities. The TRION neutron imaging system can be regarded as a stroboscopic photography of neutrons arriving at the detector on a few-ns time scale. As this spectroscopic capability is based on the Time-of-Flight (TOF) technique, it has to be operated in conjunction with a pulsed neutron source, such as an ion accelerator producing 1-2 ns wide beam pulses at MHz repetition rates. TRION is capable of capturing 4 simultaneous TOF frames within a single accelerator pulse and accumulating them over all pulses contained within a finite acquisition time. The detector principle of operation, simulations and experimental results are described. b. Fibrous optical detector A fast neutron imaging detector based on micrometric glass capillaries loaded with high- refractive-index liquid scintillator has been developed. Neutron energy spectrometry is based on event-by-event detection and reconstruction of neutron energy from the measurement of the recoil proton track projection length and the amount of light produced in the track. In addition, the detector can provide fast-neutron imaging with position resolution of tens of microns. The detector principle of operation, simulations and experimental results obtained with a small detector prototype are described. Track-imaging of individual recoil protons from incident neutrons in the range of 2-14 MeV are demonstrated as well as preliminary results of detector spectroscopic capabilities. Keywords: Fast neutron resonance radiography; Time-of-Flight; Fast neutron imaging; Energy-resolved imaging; Neutron spectrometry; Capillary array; Liquid scintillator

Explore related subjects

Keep this discovery

BibTeXRIS

Ilan Mor. 2017-04-27. High Spatial-Resolution Fast Neutron Detectors for Imaging and Spectrometry. https://arxiv.org/abs/1704.08706

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det