arXiv · 1705.06240
High voltage charging system for pulsed power generators
Abstract
A robust and portable power supply has been developed specifically for charging linear transformer drivers, a modern incarnation of fast pulsed power generators. It is capable of generator +100 kV and -100 kV at 1 mA, while withstanding the large voltage spikes generated when the pulsed-power generator is triggered. The three-stage design combines a zero-voltage switching circuit, a step-up transformer using ferrite cores, and a dual Cockcroft-Walton voltage multiplier. The zero-voltage switching circuit drives the primary of the transformer in parallel with a capacitor. With this driver, the tank circuit naturally remain in its resonant state, allowing for maximum energy coupling between the zero-voltage switching circuit and the Cockcroft-Walton voltage multiplier across a wide range of loading conditions.
Explore related subjects
Keep this discovery
M. Evans, B. Foy, D. Mager, R. Shapovalov, P. -A. Gourdain. 2017-05-12. High voltage charging system for pulsed power generators. https://arxiv.org/abs/1705.06240
Cite the original work for its findings. Save a collection to share your selection of sources.