SearcharxivSearch

arXiv · 1711.05333

Low-mass GEM detector with radial zigzag readout strips for forward tracking at the EIC

Abstract

We present design and construction of a large low-mass Triple-GEM detector prototype for forward tracking at a future Electron-Ion Collider. In this environment, multiple scattering of forward and backward tracks must be minimized so that electron tracks can be cleanly matched to calorimeter clusters and so that hadron tracks can efficiently seed RICH ring reconstruction for particle identification. Consequently, the material budget for the forward tracking detectors is critical. The construction of the detector builds on the mechanical foil stretching and assembly technique pioneered by CMS for the muon endcap GEM upgrade. As an innovation, this detector implements drift and readout electrodes on thin large foils instead of on PCBs. These foils get stretched mechanically together with three GEM foils in a single stack. This reduces the radiation length of the total detector material in the active area by a factor seven from over 4% to below 0.6%. It also aims at improving the uniformity of drift and induction gap sizes across the detector and consequently signal response uniformity. Thin outer frames custom-made from carbon-fiber composite material take up the tension from the stretched foil stack and provide detector rigidity while keeping the detector mass low. The gas volume is closed with thin aluminized polyimide foils. The trapezoidal detector covers an azimuthal angle of 30.1 degrees and a radius from 8 cm to 90 cm. It is read out with radial zigzag strips with pitches of 1.37 mrad at the outer radius and 4.14 mrad at the inner radius that reduce the number of required electronics channels and associated cost while maintaining good spatial resolution. All front-end readout electronics is located away from the active area at the outer radius of the trapezoid.

Explore related subjects

Keep this discovery

BibTeXRIS

Marcus Hohlmann, Matthew Bomberger, Stefano Colafranceschi, Francisco Jimenez, Mehdi Rahmani, Aiwu Zhang. 2017-11-14. Low-mass GEM detector with radial zigzag readout strips for forward tracking at the EIC. https://arxiv.org/abs/1711.05333

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det