Abstract
CUORE - the Cryogenic Underground Observatory for Rare Events - is an experiment searching for the neutrinoless double-beta ($0\nu\beta\beta$) decay of $^{130}$Te with an array of 988 TeO$_2$ crystals operated as bolometers at $\sim$10 mK in a large dilution refrigerator. With this detector, we aim for a $^{130}$Te $0\nu\beta\beta$ decay half-life sensitivity of $9\times10^{25}$ y with 5 y of live time, and a background index of $\lesssim 10^{-2}$ counts/keV/kg/y. Making an effort to maintain radiopurity by minimizing the bolometers' exposure to radon gas during their installation in the cryostat, we perform all operations inside a dedicated cleanroom environment with a controlled radon-reduced atmosphere. In this paper, we discuss the design and performance of the CUORE Radon Abatement System and cleanroom, as well as a system to monitor the radon level in real time.
Explore related subjects
Keep this discovery
G. Benato, D. Biare, C. Bucci, L. Di Paolo, A. Drobizhev, R. W. Kadel, Yu. G. Kolomensky, J. Schreiner, V. Singh, T. Sipla, J. Wallig, S. Zimmermann. 2017-11-21. Radon mitigation during the installation of the CUORE $0\nu\beta\beta$ decay detector. https://doi.org/10.1088/1748-0221%2F13%2F01%2Fp01010