SearcharxivSearch

arXiv · 1711.10577

Deep learning analysis of breast MRIs for prediction of occult invasive disease in ductal carcinoma in situ

Abstract

Purpose: To determine whether deep learning-based algorithms applied to breast MR images can aid in the prediction of occult invasive disease following the di- agnosis of ductal carcinoma in situ (DCIS) by core needle biopsy. Material and Methods: In this institutional review board-approved study, we analyzed dynamic contrast-enhanced fat-saturated T1-weighted MRI sequences of 131 patients at our institution with a core needle biopsy-confirmed diagnosis of DCIS. The patients had no preoperative therapy before breast MRI and no prior history of breast cancer. We explored two different deep learning approaches to predict whether there was a hidden (occult) invasive component in the analyzed tumors that was ultimately detected at surgical excision. In the first approach, we adopted the transfer learning strategy, in which a network pre-trained on a large dataset of natural images is fine-tuned with our DCIS images. Specifically, we used the GoogleNet model pre-trained on the ImageNet dataset. In the second approach, we used a pre-trained network to extract deep features, and a support vector machine (SVM) that utilizes these features to predict the upstaging of the DCIS. We used 10-fold cross validation and the area under the ROC curve (AUC) to estimate the performance of the predictive models. Results: The best classification performance was obtained using the deep features approach with GoogleNet model pre-trained on ImageNet as the feature extractor and a polynomial kernel SVM used as the classifier (AUC = 0.70, 95% CI: 0.58- 0.79). For the transfer learning based approach, the highest AUC obtained was 0.53 (95% CI: 0.41-0.62). Conclusion: Convolutional neural networks could potentially be used to identify occult invasive disease in patients diagnosed with DCIS at the initial core needle biopsy.

Explore related subjects

Keep this discovery

BibTeXRIS

Zhe Zhu, Michael Harowicz, Jun Zhang, Ashirbani Saha, Lars J. Grimm, E. Shelley Hwang, Maciej A. Mazurowski. 2017-11-28. Deep learning analysis of breast MRIs for prediction of occult invasive disease in ductal carcinoma in situ. https://arxiv.org/abs/1711.10577

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

HiPerViT: A Hierarchical Perceiver-Vision Transformer Architecture for Multi-Scale Texture Recognition

Texture recognition remains challenging for modern vision models because discriminative evidence is often carried by higher-order spatial statistics rather than by object shape alone. While Vision Transformers provide strong long-range modeling capacity, their standard object-centric representations do not explicitly expose such statistical structure, which limits texture sensitivity in fine-grained recognition settings. We present HiPerViT, a compact vision-only architecture that injects an explicit second-order statistical prior into a transformer-based recognition pipeline. The method combines global and local image views with a compact bilinear descriptor encoded as a statistical token, and integrates this token with first-order spatial representations through Perceiver-style latent distillation. This design enables direct interaction between spatial tokens and second-order feature co-occurrence statistics, providing the model with explicit access to texture-relevant information without requiring multimodal pretraining or ensemble construction. Across six texture recognition benchmarks, HiPerViT achieves consistent improvements over strong vision-only baselines under the reported evaluation protocols, including gains of +3.05 percentage points on DTD, +10.48 on GTOS-Mobile, and +10.10 on 1200Tex. Beyond benchmark performance, our analyses show that these gains are largely invariant to the backbone depth used to extract second-order statistics and to the ordering of interaction and distillation stages. This pattern suggests that the primary source of improvement is not a specific fusion topology, but the explicit availability of second-order statistical information as a first-class representational signal. These results support explicit statistical tokenization as an effective and robust design principle for texture-centric visual recognition.

cs.CV

CamPilot: A Multi-Agent Cinematic Assistant for Camera-Controlled Movie Generation

The integration of large language models (LLMs) into video generation has enabled rapid text-to-video creation and improved visual quality. However, it still falls short of professional filmmaking, where cinematographic language is less refined than human-crafted camera work and multi-shot continuity remains challenging. To address these limitations, we introduce CamPilot, a multi-agent framework that integrates cinematographic planning and camera-work control to produce more coherent, logically structured, and human-aesthetic movies. CamPilot adopts a GRPO-based learning paradigm to learn camera work planning from 14K real-world professional movies, internalizing motion patterns and composition principles that support reasoning over shooting techniques (e.g., camera angle, motion, and focal behavior) and cross-shot relationships for controllable camera-viewpoint generation. Multiple agents further collaborate and evolve to improve overall output quality. To support this work and further studies in this domain, we establish CamEval, a benchmark for evaluating camera work quality and cinematic engagement. Empirical results show that CamPilot outperforms state-of-the-art text-to-movie generation methods on cinematographic control and quality, highlighting the impact of professional camera design on movie generation.

cs.CV

New Evidence, Same Choice: Testing Physical Experiment Selection in Vision Language Models

A model first sees an image from one physical measurement experiment, such as how far a block coasted, and must answer a question about a new trial, such as whether the block will pass a target after a fixed push. The initial experiment may provide enough information to answer, or the model may need another measurement, such as the object's mass, friction, restitution, or spring stiffness. We study whether vision language models can decide when to answer immediately and, when more evidence is needed, which experiment to perform. Current physical reasoning benchmarks usually evaluate only the final answer, so they do not directly measure this decision-making ability. We introduce a controlled evaluation where each problem provides one measurement image and four possible physical worlds created by combining two possible masses and two possible values of another relevant property. The model must either stop and answer or select the cheapest additional experiment that can resolve the question. We construct matched problem pairs where changing either the observed measurement or the question changes the optimal action. Since all possible worlds and experiment costs are known, we can explicitly determine the optimal choice. Across six open models and 144 physical parameter sets, direct responses repeat the same action for 95.1% to 100% of image pairs even when the correct action changes. Brief reasoning improves action switching, but the best model makes both decisions correctly for only 5.9% of image pairs. Additional analysis reveals failures in measurement interpretation, physical reasoning, and response formatting. By evaluating evidence selection separately from final answers, our benchmark reveals limitations in physical reasoning that conventional answer accuracy can overlook.

cs.CV