Simple analytic model for radiotherapeutic X-ray induced acoustic signal as a function of absorption parameters

Abstract

It is possible to make image reconstruction based on the dose dependence of the therapeutic XA (X-ray induced acoustic signal) amplitude which is then used to make dose mapping. We give further explicit parametrization for the acoustic signal in terms of the absorption parameters based on a physical model of the absorption process. The first step is to obtain pressure waveform due to a point dose absorption by solving the thermo-acoustic equation governing the heat absorption-pressure induction process based on the analytic integration technique. Then, clinically relevant XA signal profile at the detection point is obtained by generalizing point-dose-gradient induced acoustic signal to surface-dose-gradient of a uniform spherical 3D dose distribution based on the reciprocity principle for pressure waves in fluid media. Therapeutic XA signal induced from the surface of the uniform spherical dose distribution due to X-ray irradiation onto $5x5$ $cm^2$ field of the water surface by $1~\mu s$ pulses delivering $1.7$ mGy/pulse is simulated in time and frequency domain. XA waves obtained in previous empirical studies are simulated and compared by means of shape and relative amplitude. Considering the previous studies on this subject, we believe that the significance of this study is the foundation of a novel and self-contained analytic approach to simulate the therapeutic X-ray acoustic waves based on the physical parametrization of the energy transfer process. This not only provides a better understanding of the physical phenomena underlying the medical technique in terms of the medically relevant parameters such as field size, pulse duration, absorbed dose per pulse etc. together with the physical assumptions used to obtain a solution to the photo-acoustic equation, but also brings consistent simulation results with previous experimental and k-Wave results.

Explore related subjects

Keep this discovery

BibTeXRIS

Canberk Sanli, Esra Aytac Kipergil, Mehmet Burcin Unlu. 2018-01-18. Simple analytic model for radiotherapeutic X-ray induced acoustic signal as a function of absorption parameters. https://arxiv.org/abs/1801.05956

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph