SearcharxivSearch

arXiv · 1806.06355

A High Precision Signals Readout System for Micromegas Detector Based on the VMM

Abstract

Micromegas detector is a gas detector with parallel plate structure, and it consists of a conversion gap in which radiations liberate ionization electrons and a thin amplification gap. The signal of the micromegas detector consists of two parts: the electron peak and the ion tail. The electronic signal just keeps few nanoseconds, which is used for precise time measurement. The ion signal carries most of the signal energy, and it is used to reconstruct particle energy. The micromegas detector has the advantages of high counting rate, high gain, good time resolution and position resolution, excellent radiation-hardened performance, large sensitive area and readout convenience. This paper introduces a signals readout electronics system for micromegas detector based on VMM chips. The VMM is the front end ASIC to be used in the front end electronics readout system of both the micromegas and sTGC detectors of the New Small Wheels Upgrade project. The VMM is designed by Brookhaven National Laboratory, and each chip is composed of 64 linear front-end channels. Each channel integrates a low-noise charge amplifier (CA) with adaptive feedback, test capacitor, and adjustable polarity (to process either positive or negative charge). Based on those characteristics, the VMM is applicable for the signals readout system of multichannel detectors. The readout system consists of three parts: the front-end board, the data acquisition board, and the host computer with the control software.

Explore related subjects

Keep this discovery

BibTeXRIS

Shuang. Zhou, Shengquan. Liu, Peng. Miao, Xinxin. Wang, Feng. Li, Ge. Jin, Zhilei. Zhang, Tianru. Geng. 2018-06-17. A High Precision Signals Readout System for Micromegas Detector Based on the VMM. https://arxiv.org/abs/1806.06355

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det