Evaluation of noise limits of a precision ADC for direct digital signal integration of magnetic measurements

Abstract

The characterization of laboratory plasma instabilities, magnetic reconnection and turbulence associated phenomena, require the simultaneous signal sampling from arrays of magnetic sensors (hundreds or even thousands) to obtain spatial resolution, with several hundred kHz for time resolution. Magnetic measurements based on pick-up (Mirnov) coil are quite common in experimental pulsed devices for plasma research, thanks to their simplicity and reliability. Being the signal from this type of sensor proportional to the time variation of the magnetic field ($dB/dt$), it has to be time-integrated to recover the instant value of magnetic field. Depending on the required integration time usually either analog integrators or chopped integrators are used. However these solutions tend to limit the frequency bandwidth in the kHz range, they are not easy to design and build, and require additional fast channels to directly acquire the $dB/dt$ signal to recover the plasma dynamic features at higher frequencies. In this paper we evaluate the feasibility of using a direct single channel precision ADC to allow the simultaneous acquisition of $dB/dt$ measurements and to provide the integrated B measurement by means of digital integration on the new RFX-mod2 device. On this purpose we interfaced an existing ADC-module to a Xilinx Zynq FPGA, in order to evaluate the intrinsic noise and to investigate the feasible integration window of this configuration. The result opens the door to a compact, cost-effective and reliable acquisition system, usable for simultaneous real-time control and transient signal recording, scalable from tenths to thousands channels, applicable to a broad class of pulsed plasma experimental devices.

Explore related subjects

Keep this discovery

BibTeXRIS

Roberto Cavazzana, Marco Gottardo, Andrea Rigoni Garola. 2018-06-20. Evaluation of noise limits of a precision ADC for direct digital signal integration of magnetic measurements. https://arxiv.org/abs/1806.07886

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det