SearcharxivSearch

arXiv · 1806.10456

Real-time Data Acquisition and Processing System for MHz Repetition Rate Image Sensors

Abstract

One of the optimization goals of a particle accelerator is to reach the highest possible beam peak current. For that to happen the electron bunch propagating through the accelerator should be kept relatively short along the direction of its travel. In order to obtain a better understanding of the beam composition it is crucial to evaluate the electric charge distribution along the micrometer-scale packets. The task of the Electro-Optic Detector (EOD) is to imprint the beam charge profile on the spectrum of light of a laser pulse. The actual measurement of charge distribution is then extracted with a spectrometer based on a diffraction grating. The article focuses on developed data acquisition and processing system called the High-speed Optical Line Detector (HOLD). It is a 1D image acquisition system which solves several challenges related to capturing, buffering, processing and transmitting large data streams with use of the FPGA device. It implements a latency-optimized custom architecture based on the AXI interfaces. The HOLD device is realized as an FPGA Mezzanine Card (FMC) carrier with single High Pin-Count connector hosting the KIT KALYPSO detector. The solution presented in the paper is probably one of the world fastest line cameras. Thanks to its custom architecture it is capable of capturing at least 10 times more frames per second than fastest comparable commercially available devices.

Explore related subjects

Keep this discovery

BibTeXRIS

Aleksander Mielczarek, Dariusz Makowski, Andrzej Napieralski, Christopher Gerth, Bernd Steffen. 2018-06-27. Real-time Data Acquisition and Processing System for MHz Repetition Rate Image Sensors. https://arxiv.org/abs/1806.10456

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det