SearcharxivSearch

arXiv · 1807.02052

Which is better, a SCoTSS gamma imager, or an ARDUO UAV-borne directional detector?

Abstract

The SiPM-based Compton Telescope for Safety and Security (SCoTSS) has been developed with inorganic crystalline scintillator material for gamma detection. The instrument is sensitive enough to be used in a mobile survey mode, accumulating energy deposited in any crystal second-by-second and tagging these spectra with GPS position. The SCoTSS imager of course has the additional advantage of being able to produce an image of the radioactive objects in its field of view using events that satisfy a coincidence trigger between the scatter and absorber layers. The Advanced Radiation Detector for UAV Operations (ARDUO) on the other hand, is a non-imaging directional detector intended for use aboard a small unmanned aerial vehicle (UAV). The ARDUO detector features exactly the same volume of CsI(Tl) as is used in the absorber layer of a single SCoTSS module, giving it similar detection and alarming sensitivity, and map-making capability. However, in the ARDUO detector, the crystals are arranged closely together to optimize direction determination from self-shielding effects. Flown in a grid pattern with a UAV over an area of extended contamination, the ARDUO detector is also capable of making a map or image of that area. With its close-packed crystal arrangement, the ARDUO detector makes a poor Compton imager but does have some ability to produce a peripheral image in a fly-by. In this presentation we investigate the relative merits of Compton imaging versus mobile directional detection.

Explore related subjects

Keep this discovery

BibTeXRIS

Andrew McCann, Laurel E. Sinclair, Patrick R. B. Saull, Christian Van Ouellet, Richard Fortin, Carolyn Chen, Maurice J. Coyle, Rodger Mantifel, Audrey M. L. MacLeod, Reid A. Van Brabant, John Buckle, Pierre-Luc Drouin, Jens Hovgaard, Bohdan Krupskyy, Blake Beckman, Blaine Fairbrother. 2018-07-05. Which is better, a SCoTSS gamma imager, or an ARDUO UAV-borne directional detector?. https://arxiv.org/abs/1807.02052

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det