SearcharxivSearch

arXiv · 1807.07787

Upgrade of the ALICE central barrel tracking detectors: ITS and TPC

Abstract

The ALICE Collaboration will undertake a major upgrade of the detector apparatus during the second LHC Long Shutdown LS2 (2019-2020) in view of the Runs 3 and 4 (2021-2029). The objective of the upgrade is two-fold: i) an improvement of the tracking precision and efficiency, in particular in the low-momentum range; ii) an improvement of the readout capabilities of the experiment, in order to fully exploit the luminosity for heavy ions envisaged after LS2. The first goal will be achieved by replacing the Inner Tracking System with a new tracker, composed of seven layers of silicon pixel detectors. The new tracker will be made up of about 25000 Monolithic Active Pixel Sensors with fast readout, resulting in a material thickness reduced to 0.3% (inner layers) - 1% (outer layers) of the radiation length and a granularity of $28\times28$ $μ$m$^2$. The second goal will be achieved, among other measures, by replacing the readout chambers of the 90 m$^3$ Time Projection Chamber with Micro Pattern Gaseous Detectors. In particular, the new readout chambers will consist of stacks of 4 Gas Electron Multiplier foils combining different hole pitches. The upgraded detector will operate continuously without the use of a triggered gating grid. It will thus be able to record all Pb--Pb collisions at the LHC interaction rate of 50 kHz.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gasik fo the ALICE Collaboration. 2018-07-20. Upgrade of the ALICE central barrel tracking detectors: ITS and TPC. https://doi.org/10.1016/j.nuclphysa.2018.08.022

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det