SearcharxivSearch

arXiv · 1808.06353

Optimal illumination pattern for transport-of-intensity quantitative phase microscopy

Abstract

The transport-of-intensity equation (TIE) is a well-established non-interferometric phase retrieval approach, which enables quantitative phase imaging (QPI) of transparent sample simply by measuring the intensities at multiple axially displaced planes. Nevertheless, it still suffers from two fundamentally limitations. First, it is quite susceptible to low-frequency errors (such as \cloudy" artifacts), which results from the poor contrast of the phase transfer function (PTF) near the zero frequency. Second, the reconstructed phase tends to blur under spatially low-coherent illumination, especially when the defocus distance is beyond the near Fresnel region. Recent studies have shown that the shape of the illumination aperture has a significant impact on the resolution and phase reconstruction quality, and by simply replacing the conventional circular illumination aperture with an annular one, these two limitations can be addressed, or at least significantly alleviated. However, the annular aperture was previously empirically designed based on intuitive criteria related to the shape of PTF, which does not guarantee optimality. In this work, we optimize the illumination pattern to maximize TIE's performance based on a combined quantitative criterion for evaluating the \goodness" of an aperture. In order to make the size of the solution search space tractable, we restrict our attention to binary coded axis-symmetric illumination patterns only, which are easier to implement and can generate isotropic TIE PTFs. We test the obtained optimal illumination by imaging both a phase resolution target and HeLa cells based on a small-pitch LED array, suggesting superior performance over other suboptimal patterns in terms of both signal-to-noise ratio (SNR) and spatial resolution.

Explore related subjects

Keep this discovery

BibTeXRIS

Jiaji Li, Qian Chen, Jiasong Sun, Jialin Zhang, Xiangpeng Pan, Chao Zuo. 2018-08-20. Optimal illumination pattern for transport-of-intensity quantitative phase microscopy. https://doi.org/10.1364/oe.26.027599

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Exponential Pixelating Integral transform with dual fractal features for enhanced chest X-ray abnormality detection

The heightened prevalence of respiratory disorders, particularly exacerbated by a significant upswing in fatalities due to the novel coronavirus, underscores the critical need for early detection and timely intervention. This imperative is paramount, possessing the potential to profoundly impact and safeguard numerous lives. Medically, chest radiography stands out as an essential and economically viable medical imaging approach for diagnosing and assessing the severity of diverse Respiratory Disorders. However, their detection in Chest X-Rays is a cumbersome task even for well-trained radiologists owing to low contrast issues, overlapping of the tissue structures, subjective variability, and the presence of noise. To address these issues, a novel analytical model termed Exponential Pixelating Integral is introduced for the automatic detection of infections in Chest X-Rays in this work. Initially, the presented Exponential Pixelating Integral enhances the pixel intensities to overcome the low-contrast issues that are then polar-transformed followed by their representation using the locally invariant Mandelbrot and Julia fractal geometries for effective distinction of structural features. The collated features labeled Exponential Pixelating Integral with dually characterized fractal features are then classified by the non-parametric multivariate adaptive regression splines to establish an ensemble model between each pair of classes for effective diagnosis of diverse diseases. Rigorous analysis of the proposed classification framework on large medical benchmarked datasets showcases its superiority over its peers by registering a higher classification accuracy and F1 scores ranging from 98.46 to 99.45% and 96.53-98.10% respectively, making it a precise and interpretable automated system for diagnosing respiratory disorders.

eess.IV

Myocardial Strain Drift Correction in Deep Learning Based Ultrasound Tracking

Myocardial strain from echocardiography is a key biomarker for cardiac function. Recent deep learning methods show strong performance for myocardial motion tracking but often lack physiological constraints, leading to temporal drift across the cardiac cycle. Consequently, tracked points may not return to their relative initial positions at the end of each cardiac cycle, producing inaccurate strain estimates and even divergence in some cases. We propose a deep learning framework that compensates for drift during myocardial tracking. We extend a state-of-the-art echocardiographic tracking method (TAS-Net) with persistent memory tokens that share information across sliding windows over full cardiac cycles. A teacher-student fine-tuning strategy on real echocardiographic data then enforces physiologically consistent cyclic motion while preserving tracking accuracy. Experiments show reduced global and regional strain drift, improved agreement with clinical references, and better test-retest reproducibility, supporting more reliable myocardial strain estimation in clinical practice.

eess.IV

Morphological Decoupling-Based Skeletal Classification for Clinical Assessment of Malocclusion

Malocclusion skeletal grading is a fundamental task in orthodontics, critical for diagnosis and treatment planning. Traditionally, cone-beam computed tomography (CBCT) is used for visual measurement, and the reconstructed lateral cephalograms are handed over to expert dentists for diagnosis. However, manual review is time-consuming, labor-intensive, and subject to inter-operator variability. Therefore, an automatic CBCT-based system is needed for reliable malocclusion skeletal grading. In this case, we develop TeethGNN, a novel graph-based framework designed to combine CBCT image features with morphological information for accurate and efficient malocclusion grading. TeethGNN utilizes a decoupled learnable decoder to directly predict key morphological indicators from CBCT images, eliminating the need for manual measurements. These morphological features are then fused with image features using a graph neural network (GNN), which effectively models the relationships between the modalities. To further enhance robustness and calibration, we introduce a collaborative calibration strategy. This strategy combines multi-scale graph adversarial perturbation for explicit calibration and nonlinear topological graph calibration for implicit confidence adjustment. Extensive experiments and ablation studies on our collected clinical dataset demonstrate that our malocclusion measurement system achieves 77.08\% in accuracy and 89.61\% in AUC, outperforming the compared state-of-the-art methods. These results validate the effectiveness of graph-based multimodal fusion and collaborative calibration in improving malocclusion grading performance. Our system shows strong potential for advancing computer-aided orthodontic diagnosis, providing an accurate and reliable solution for vision-based clinical measurement and diagnosis.

eess.IV