SearcharxivSearch

arXiv · 1808.06827

Characterisation of Silicon Photomultipliers for Liquid Xenon Detectors

Abstract

Silicon Photomultipliers (SiPMs) are considered as a solid-state sensor alternative to photomultiplier tubes in experiments using liquid xenon (LXe) as a radiation detection medium. The main requirements are single-photon detection of the vacuum ultraviolet scintillation light from LXe at 178$\,$nm with high resolution and detection efficiency and low noise rates. Further requirements for dark matter and double beta decay searches are ultra-low radioactivity levels of all the components including the substrates and cold electronics. Here we describe our characterisation of Hamamatsu 6$\times$6$\,$mm$^2$ SiPMs in the temperature range 110-300$\,$K in nitrogen gas, as well as long-term measurements in cold nitrogen gas at 172$\,$K and liquid xenon at 185$\,$K. After we introduce the experimental setups, the data acquisition schemes and analysis methods, we show the single-photon response, the gain versus bias voltage, as well as the dark and correlated noise rates. We demonstrate the long-term stability at cryogenic temperatures, and conclude that SiPM arrays are promising candidates for photosensor arrays in liquid xenon detectors. Furthermore, we study the radioactivity of the raw SiPM materials with gamma spectrometry and inductively coupled plasma mass spectrometry and conclude that SiPMs are suitable for use in low-background experiments.

Explore related subjects

Keep this discovery

BibTeXRIS

Laura Baudis, Michelle Galloway, Alexander Kish, Chris Marentini, Julien Wulf. 2018-08-21. Characterisation of Silicon Photomultipliers for Liquid Xenon Detectors. https://doi.org/10.1088/1748-0221%2F13%2F10%2Fp10022

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det