Model Based In Situ Calibration with Temperature compensation of 6 axis Force Torque Sensors
Abstract
It is well known that sensors using strain gauges have a potential dependency on temperature. This creates temperature drift in the measurements of six axis force torque sensors (F/T). The temperature drift can be considerable if an experiment is long or the environmental conditions are different from when the calibration of the sensor was performed. Other \textit{in situ} methods disregard the effect of temperature on the sensor measurements. Experiments performed using the humanoid robot platform iCub show that the effect of temperature is relevant. The model based \textit{in situ} calibration of six axis force torque sensors method is extended to perform temperature compensation.
Explore related subjects
Keep this discovery
Francisco Javier Andrade Chavez, Gabriele Nava, Silvio Traversaro, Francesco Nori, Daniele Pucci. 2018-12-03. Model Based In Situ Calibration with Temperature compensation of 6 axis Force Torque Sensors. https://arxiv.org/abs/1812.00650