SearcharxivSearch

arXiv · 1903.10291

Gas modulation refractometry (GAMOR) - On its ability to eliminate the influence of drifts

Abstract

Gas modulation refractometry (GAMOR) is a technique based on a dual-Fabry-Perot (FP) cavity (DFPC) for assessment of gas refractivity, density, and pressure that can alleviate significant limitations of conventional refractometry systems, predominantly those related to drifts. Repeated assessments of the beat frequency when the measurement cavity is evacuated provide conditions under which the methodology is immune to the linear parts of the drifts in the system, both those from length changes of the cavities and those from gas leaks and outgassing. This implies that the technique is solely influenced by the non-linear parts of the drifts. This work provides a description of the principle behind the GAMOR methodology and explicates the background to its unique property. Based on simple models of the drifts of the temperature in the cavity spacer and the residual gas in the reference cavity, this work predicts that a GAMOR system, when used for assessment of refractivity, can sustain significant temperature drifts and leakage rates without being affected by noticeable errors or uncertainties. The cavity spacer can be exposed to temperature fluctuations of 100 mK over 103 s, and the reference cavity can have a leakage that fills it up with gas on a timescale of days, without providing errors or uncertainties in the assessment of refractivity that are 3 x 10^(-12), which, for N2, corresponds to 0.01 ppm (parts per million) of the value under atmospheric pressure conditions, and thereby 1 mPa. Since well-designed systems often have temperature fluctuations and leakage rates that are smaller than these, it is concluded that there will, in practice, not be any appreciable influence from cavity length drifts, gas leaks, and outgassing in the GAMOR methodology.

Explore related subjects

Keep this discovery

BibTeXRIS

Ove Axner, Isak Silander, Clayton Forssén, Yin Guo, Martin Zelan. 2019-03-25. Gas modulation refractometry (GAMOR) - On its ability to eliminate the influence of drifts. https://arxiv.org/abs/1903.10291

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det