Rapid measurement of tension in multi-wire arrays using free damped oscillations

Abstract

We explore the possibility of using free (as opposed to driven) oscillations to verify wire tension in large, open-frame multiwire planes. Using finite-element simulation we predict the signal when two wires are set in motion by applying and holding a DC voltage between them (electrostatic excitation). The resulting current signal is marginal. However, the program relates voltage, oscillation amplitude and signal, and it is easy to get enough amplitude (of order microns) by gently tapping the wire frame. We perform an end-to-end experimental test. Four 1.5m wires, at various tensions around 5N, are mounted in an aluminum channel. They are connected to a low-noise, balanced current-to-voltage preamp designed for good common-mode rejection. The 150V bias, from 9V batteries in series, is built into the preamp. Data are taken with a Tektronix 1202B scope, stored on a USB flash drive, and transferred to a laptop computer for analysis. Ten measurements, each with 2500 samples spanning 1s, are taken for each of the three wire pairs. The wires are excited by tapping the frame with a small mallet. Because the wire tensions are different, the waveforms exhibit beats. The data are analyzed by a program which decomposes the waveform step by step to extract the base and beat frequencies and thereby, two resonant frequencies per wire pair. Finally, those frequencies are disambiguated to obtain the frequency for each wire, which is then converted to a tension. The four tensions are then found mechanically by measuring the g/mm required to deflect each wire at its midpoint. The two values of tension agree well. We conclude that the method verifies tension to approximately 2% (1 sigma) in a little over 1s for 1.5m wires, and would be faster for shorter wires.

Explore related subjects

Keep this discovery

BibTeXRIS

Bernard Gottschalk. 2019-05-21. Rapid measurement of tension in multi-wire arrays using free damped oscillations. https://arxiv.org/abs/1905.08884

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det