Using infrared gas sensors in an in-vitro dynamic gut model for detecting short-chain fatty-acids: Technical Report

Abstract

Short-chain fatty acids (SCFAs), including acetate, propionate and butyrate, are organic fatty-acids that are produced when indigested carbohydrates are fermented in the colon by gut-bacteria. Butyrate is especially considered a beneficial compound in relation to gut health and the maintenance of colonic homeostasis. Little is known about butyrate production and the current measurement methods of fecal samples are not representative and there is a strong unmet need to measure SCFAs in-vivo to further understand their role and effect on colonic function in human gut health and disease. The general aim of the project is to develop a novel sensor based on infrared technology that is capable of online detecting short chain fatty acids (SCFA; e.g. acetate, propionate and butyrate) and other small biomolecules (e.g. ammonium) produced in bioreactors. Whereas currently such levels of small biomolecules are usually not detected online due to practical constraints (sampling-analysis-processing of data), reliable online detection could significantly decrease analysis costs. Further, it would allow to perform online quality control of the bioreactors and allow to e.g. detect deviating values at an early stage. Hence, one can react much faster tackling certain problems which will further improve the quality of each experiment. Using machine learning algorithms to process the sensor signals, the results from testing in a so-called artificial gut setup are described in this technical report.

Explore related subjects

Keep this discovery

BibTeXRIS

Martin Längkvist, Amy Loutfi, Igancio Rangel, Johnny Karlsson, Robert Jan Brummer. 2019-08-22. Using infrared gas sensors in an in-vitro dynamic gut model for detecting short-chain fatty-acids: Technical Report. https://arxiv.org/abs/1909.11177

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det