SearcharxivSearch

arXiv · 2003.12229

Co-precipitation approach to measure amount of $^{238}$U in copper to sub-ppt level using ICP-MS

Abstract

Inductively coupled plasma mass (ICP-MS) spectroscopy is widely used for screening materials of low background detectors in dark matter and double beta decay searches due to its high sensitivity to trace $^{238}$U and $^{232}$Th. This work describes a novel co-precipitation approach to measure the amount of $^{238}$U in high-purity copper to sub-ppt level. Such an approach allows the pre-concentration of U and removal of the matrix, by selecting a proper precipitator to co-precipitate with $^{238}$U and using excess ammonia water to separate the uranium hydroxide from copper by forming water-soluble tetra-amminecopper (II). The isotope dilution method and standard addition method were both used to mitigate the matrix effect and cross-check each other. The latter was also used to measure the recovery efficiency of $^{238}$U by using $^{233}$U as the tracer. The method detection limit (MDL) reached $\sim$0.1 pg $^{238}$U /g Cu for both methods while the recovery efficiency of uranium robustly remains 65\%--85\%. Various sources of interference in the ICP-MS analysis were thoroughly evaluated, and the contamination from reagents were found to be the dominant factor that affected the MDL. Further purification will allow significant improvements in the MDL. This co-precipitate approach can be easily extended to measure $^{232}$Th by using $^{229}$Th as the tracer.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ya-Yun Ding, Meng-Chao Liu, Jie Zhao, Wen-Qi Yan, Liang-Hong Wei, Zhi-Yong Zhang, Liang-Jian Wen. 2020-03-27. Co-precipitation approach to measure amount of $^{238}$U in copper to sub-ppt level using ICP-MS. https://doi.org/10.1016/j.nima.2019.162335

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det