arXiv · 2005.03903
Improving the time resolution of the MRPC detector using deep-learning algorithms
Abstract
The multi-gap resistive plate chambers (MRPCs) will be used as the Time-of-Flight (ToF) system in the Solenoidal Large Intensity Device (SoLID). The time resolution required by the experiment for the MRPC system is 20 ps in order to make a 3 $\sigma$ separation of the $\pi/K$ created in the collisions. To achieve this goal, the whole system including the MRPC detector, the front-end electronics and the readout system will be upgraded. Based on the new system, a time reconstruction algorithm using a combined LSTM (ComLSTM) neural network is proposed. The best time resolution achieved with this algorithm in a cosmic ray test is 16.8 ps, which largely improves the timing ability of the MRPC detector and well satisfies the requirement of the SoLID.
Explore related subjects
Keep this discovery
Fuyue Wang, Dong Han, Yi Wang. 2020-05-08. Improving the time resolution of the MRPC detector using deep-learning algorithms. https://arxiv.org/abs/2005.03903
Cite the original work for its findings. Save a collection to share your selection of sources.