SearcharxivSearch

arXiv · 2005.04892

Detection of metastable electronic states by Penning trap mass spectrometry

Abstract

State-of-the-art optical clocks achieve fractional precisions of $10^{-18}$ and below using ensembles of atoms in optical lattices or individual ions in radio-frequency traps. Promising candidates for novel clocks are highly charged ions (HCIs) and nuclear transitions, which are largely insensitive to external perturbations and reach wavelengths beyond the optical range, now becoming accessible to frequency combs. However, insufficiently accurate atomic structure calculations still hinder the identification of suitable transitions in HCIs. Here, we report on the discovery of a long-lived metastable electronic state in a HCI by measuring the mass difference of the ground and the excited state in Re, the first non-destructive, direct determination of an electronic excitation energy. This result agrees with our advanced calculations, and we confirmed them with an Os ion with the same electronic configuration. We used the high-precision Penning-trap mass spectrometer PENTATRAP, unique in its synchronous use of five individual traps for simultaneous mass measurements. The cyclotron frequency ratio $R$ of the ion in the ground state to the metastable state could be determined to a precision of $\delta R=1\cdot 10^{-11}$, unprecedented in the heavy atom regime. With a lifetime of about 130 days, the potential soft x-ray frequency reference at $\nu=4.86\cdot 10^{16}\,\text{Hz}$ has a linewidth of only $\Delta \nu\approx 5\cdot 10^{-8}\,\text{Hz}$, and one of the highest electronic quality factor ($Q=\frac{\nu}{\Delta \nu}\approx 10^{24}$) ever seen in an experiment. Our low uncertainty enables searching for more HCI soft x-ray clock transitions, needed for promising precision studies of fundamental physics in a thus far unexplored frontier.

Explore related subjects

Keep this discovery

BibTeXRIS

Rima Xenia Schüssler, Hendrik Bekker, Martin Braß, Halil Cakir, José R. Crespo López-Urrutia, Menno Door, Pavel Filianin, Zoltan Harman, Maurits W. Haverkort, Wen Jia Huang, Paul Indelicato, Christoph Helmut Keitel, Charlotte Maria König, Kathrin Kromer, Marius Müller, Yuri N. Novikov, Alexander Rischka, Christoph Schweiger, Sven Sturm, Stefan Ulmer, Ssergey Eliseev, Klaus Blaum. 2020-05-11. Detection of metastable electronic states by Penning trap mass spectrometry. https://doi.org/10.1038/s41586-020-2221-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Delay-engineered dynamical phases in a programmable non-Markovian spin oscillator

Non-Markovian dynamics offer a new route towards engineering non-equilibrium matter, where memory and feedback act as programmable resources for controlling order in time. Here we report the realization of a non-Markovian spin oscillator in a hot vapour $^{129}$Xe-Cs co-magnetometer with programmable feedback delay and gain. By tuning these parameters, we observe a hierarchy of dynamical phases, including time-crystalline response, nonlinear bifurcations, and frequency-comb formation. The measured spectra and phase boundaries are captured by linear stability analysis of delayed Bloch equations, revealing these phenomena as different manifestations of the same memory-induced instability structure. These results establish time-delayed feedback as a powerful strategy for controlling non-equilibrium phases, enabling quantum sensing, frequency referencing, and synchronization within a single spin-based platform.

physics.atom-ph

Non-stick vacuum wall collisions with a laser-coolable molecule

Molecular species that are suitable for direct laser cooling are typically considered lost or destroyed if they collide with an ambient temperature vacuum wall. Here, we study surface collisions with aluminum monofluoride (AlF), a laser-coolable molecule that survives this process with unusually high probability. We detect the outgoing AlF molecules from a single wall collision via Doppler-sensitive laser-induced fluorescence spectroscopy, using incoming supersonic (pulsed) and thermochemical (continuous) molecular beams. The angular, velocity and rovibrational level distributions of the outgoing molecules show near-complete thermalisation to the wall in a single collision event. We determine an upper limit to the surface residence time of about 5$~\mu$s, and by monitoring the decay in density of pulses of molecules loaded into a small storage volume, we deduce the surface sticking probability for different materials. For a siloxane-coated metallic surface, the sticking probability of AlF is about 0.015, allowing us to accumulate molecules from the thermochemical source into an ambient temperature storage vessel at densities near $10^{8}~$cm$^{-3}$. This provides a route to compact, portable traps for neutral molecules.

physics.atom-ph

Kinetic modeling of molecular beam formation in a cryogenic buffer-gas cell

Cryogenic buffer-gas cells are widely used to produce cold molecular beams, but the microscopic dynamics governing beam formation remain challenging to model. Here we present fully kinetic simulations of a cryogenic buffer-gas cell using the Direct Simulation Monte Carlo method implemented in the PICLas framework, treating the buffer gas and ablated molecules within a single unified model. We capture characteristic features of cryogenic buffer-gas sources, including plume cooling, directed transport toward the aperture, and the formation of a slow molecular beam, while also resolving energy transfer from the hot ablation plume to the helium buffer gas that is inaccessible to existing approaches relying on the background-gas approximation. Our results demonstrate that fully kinetic simulations can provide detailed insights into buffer-gas cell dynamics and open a route toward a systematic optimization of such sources.

physics.atom-ph