SearcharxivSearch

arXiv · 2005.06131

Enhancement of low-spatial-frequency components by a new phase-contrast STEM using a probe formed with an amplitude Fresnel zone plate

Abstract

Electron microscopy is a powerful tool for visualizing the shapes of sub-nanometer objects. However, contrast is not in proportional to density distribution, and therefore achieving a quantitative understanding of specimens is not straightforward, especially for low-contrast subjects such as biological specimens. To overcome this problem, we have developed a new phase-contrast scanning transmission electron microscope (STEM) in which a probe beam formed with an amplitude Fresnel zone plate (FZP) and the resulting interference patterns produced by the zeroth and first order diffracted waves generated by the FZP are detected. We name it FZP-PC-STEM hereinafter. The amplitude FZP was manufactured by using focused ion beam (FIB) equipment, and the diffraction data were collected by using diffraction imaging technique. The validity of our proposed optical model was confirmed by comparing experimental and simulated images. Observations of carbon nanotube (CNT) bundles by this method showed that the contrast of low-spatial-frequency components in the CNT image was enhanced, unlike the case in conventional bright-field STEM. This method does not, in principle, require the post-image processing used in the diffraction imaging method, and it can be easily introduced into a conventional STEM system without major modifications. The stability and robustness of the method toward intense electron irradiation during long-time operation were also confirmed. We expect that the FZP-PC-STEM will be widely applicable to quantitative observations of radiation-sensitive light-element specimens, with simple and easy operation.

Explore related subjects

Keep this discovery

BibTeXRIS

Masato Tomita, Yukinori Nagatani, Kazuyoshi Murata, Atsushi Momose. 2020-05-13. Enhancement of low-spatial-frequency components by a new phase-contrast STEM using a probe formed with an amplitude Fresnel zone plate. https://arxiv.org/abs/2005.06131

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det