Establishing correction solutions for Scanning Laser Doppler Vibrometer measurements affected by sensor head vibration

Abstract

Scanning Laser Doppler Vibrometer (SLDV) measurements are affected by sensor head vibrations as if they are vibrations of the target surface itself. This paper presents practical correction schemes to solve this important problem. The study begins with a theoretical analysis, for arbitrary vibration and any scanning configuration, which shows that the only measurement required is of the vibration velocity at the incident point on the final steering mirror in the direction of the outgoing laser beam and this underpins the two correction options investigated. Correction sensor location is critical; the first scheme uses an accelerometer pair located on the SLDV front panel, either side of the emitted laser beam, while the second uses a single accelerometer located along the optical axis behind the final steering mirror. Initial experiments with a vibrating sensor head and stationary target confirmed the sensitivity to sensor head vibration together with the effectiveness of the correction schemes which reduced overall error by 17 dB (accelerometer pair) and 27 dB (single accelerometer). In extensive further tests with both sensor head and target vibration, conducted across a range of scan angles, the correction schemes reduced error by typically 14 dB (accelerometer pair) and 20 dB (single accelerometer). RMS phase error was also up to 30% lower for the single accelerometer option, confirming it as the preferred option. The theory suggests a geometrical weighting of the correction measurements and this provides a small additional improvement. Since the direction of the outgoing laser beam and its incident point on the final steering mirror both change as the mirrors scan the laser beam, the use of fixed axis correction transducers mounted in fixed locations makes the correction imperfect. The associated errors are estimated and expected to be generally small, and the theoretical basis...

Explore related subjects

Keep this discovery

BibTeXRIS

Ben J. Halkon, Steve J. Rothberg. 2020-06-19. Establishing correction solutions for Scanning Laser Doppler Vibrometer measurements affected by sensor head vibration. https://arxiv.org/abs/2006.10918

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det