A plan quality control method of treatment planning for Gamma Knife radiosurgery

Abstract

With many variables to adjust, conventional manual forward planning for Gamma Knife (GK) radiosurgery is very complicated and cumbersome. The resulting plan quality heavily depends on planners skills, experiences and devoted efforts, and varies significantly among cases, planners, and institutions. Quality control for GK planning is desired to consistently provide high-quality plan to each patient. In this study, we proposed a quality control method for GK planning by building a database of high-quality GK plans. Patient anatomy was described by target volume, target shape complexity, and spatial relationship between target and nearby organs, which determine GK planning difficulty level. Plan quality was evaluated using target coverage, selectivity, intermediate dose spillage, maximum dose to 0.1 cc of brainstem, mean dose of ipsilateral cochlea, and beam-on time. When a new plan is created, a high-quality plan that has the most similar target volume size and shape complexity will be identified from the database. A model has also been built to predict the dose to brainstem and cochlea based on their overlap volume histograms. The identified reference plan and the predicted organ dose will help planners to make quality control decisions accordingly. To validate this method, we have built a database for vestibular schwannoma, which are considered to be challenging for GK planning due to the irregularly-shaped target and its proximity to brainstem and cochlea. Five cases were tested, among which one case was considered to be of high quality and four cases had a lower plan quality than prediction. These four cases were replanned and got substantially improved. Our results have demonstrated the efficacy of our proposed quality control method. This method may also be used as a plan quality prediction method to facilitate the development of automatic treatment planning for GK radiosurgery.

Explore related subjects

Keep this discovery

BibTeXRIS

Tonghe Wang, Matt D. Giles, Elizabeth Butker, Matthew C. Walb, Xiaofeng Yang, Tian Liu, Shannon Kahn, Zhen Tian. 2020-09-15. A plan quality control method of treatment planning for Gamma Knife radiosurgery. https://arxiv.org/abs/2009.06813

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph