SearcharxivSearch

arXiv · 2009.09839

Geant4 Systematic Study of the FRACAS Apparatus for Hadrontherapy Cross Section Measurements

Abstract

In this work, we report on systematic Monte Carlo (MC) studies for the FRACAS apparatus, a large acceptance mass spectrometer that will be used to measure the fragmentation cross sections of $^{12}$C ions for hadrontherapy. The apparatus placed, in a 100 mbar reaction chamber, will be made of a beam monitor, trackers surrounding a magnet and a Time-Of-Flight (TOF) wall. In order to determine the required performances of the trackers, Geant4 simulations of the whole system and in-house developed algorithms were used. While keeping the beam monitor and TOF-wall positions fixed, the effects of the tracker positions and spatial resolutions on the trajectory reconstruction and mass identification efficiencies have been extracted. An optimal configuration was found where the upstream trackers should be located 6 cm away from the target and spaced 4 cm apart whereas their spatial resolutions should be close to 100 $\mu$m. The positions of the downstream trackers will have to be changed according to the beam energy to preserve high identification efficiencies. Their spatial resolutions, even though of a lesser importance compared to the upstream trackers, should be around 1 mm or better. In this optimal configuration, an overall fragment identification efficiency above 90% has been obtained for beam energies ranging from 100 to 400 MeV/nucleon.

Explore related subjects

Keep this discovery

BibTeXRIS

Edgar Barlerin, Samuel Salvador, Marc Labalme. 2020-09-17. Geant4 Systematic Study of the FRACAS Apparatus for Hadrontherapy Cross Section Measurements. https://doi.org/10.1088/1748-0221%2F16%2F02%2Fp02013

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det