SearcharxivSearch

arXiv · 2009.14696

Silicon carbide diodes for neutron detection

Abstract

In the last two decades we have assisted to a rush towards finding a He3-replacing technology capable of detecting neutrons emitted from fissile isotopes. The demand stems from applications like nuclear war-head screening or preventing illicit traffic of radiological materials. Semiconductor detectors stand among the stronger contenders, particularly those based on materials possessing a wide band gap like silicon carbide. We review the workings of SiC-based neutron detectors, along with several issues related to material properties, device fabrication and testing. The paper summarizes the experimental and theoretical work carried out within the E-SiCure project, co-funded by the NATO SPS Programme. Among the achievements, we have the development of successful Schottky barrier based detectors and the identification of the main carrier life-time-limiting defects in the SiC active areas, either already present in pristine devices or introduced upon exposure to radiation fields. The physical processes involved in neutron detection are described. Material properties as well as issues related to epitaxial growth and device fabrication are addressed. The presence of defects in as-grown material, as well as those introduced by ionizing radiation are reported. We finally describe several experiments carried out at the Jozef Stefan Institute TRIGA Mark II reactor (Ljubljana, Slovenia), where a set of SiC-based neutron detectors were tested, some of which being equipped with a thermal neutron converter layer. We show that despite the existence of large room for improvement, Schottky barrier diodes based on state-of-the-art 4H-SiC are closing the gap regarding the sensitivity offered by gas-based and that of semiconductor detectors.

Explore related subjects

Keep this discovery

BibTeXRIS

José Coutinho, Vitor J. B. Torres, Ivana Capan, Tomislav Brodar, Zoran Ereš, Robert Bernat, Vladimir Radulović, Klemen Ambrožič, Luka Snoj, Željko Pastuović, Adam Sarbutt, Takeshi Ohshima, Yuichi Yamazaki, Takahiro Makino. 2020-09-30. Silicon carbide diodes for neutron detection. https://doi.org/10.1016/j.nima.2020.164793

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det