Actinium-225 Production with an Electron Accelerator

Abstract

There has been growing clinical evidence of the value of targeted alpha therapy for treatment of several cancers. The work has been slowed by the lack of availability of the key alpha emitting isotopes, especially Ac-225. Until this time, most of the supply has been from three Th-229 generators that are milked to produce hundreds of mCi of Ac-225 every month. There has been a growing effort to produce new sources of Ac-225 from several different accelerator-based routes. It can be produced with medical-isotope cyclotrons with a proton energy of at least 16 MeV using the reaction Ra-226(p,2n)Ac-225. It can also be produced by using high-energy protons (150 to 800 MeV) for spallation of a thorium target. Significant experimental work has been applied to both processes. It can also be produced by the photonuclear reaction, Ra-226(γ,n)Ra-225. The Ra-225 decays via beta decay to Ac-225 with a half life of 14.9 days. The photons are produced by an intense beam of electrons with an energy about 25 to 30 MeV. This paper will provide a technical description of radium targets and a target chamber that would be capable of producing a yield of four curies of Ra-225 from a 10-day irradiation of one gram of radium segmented into two to four separate encapsulated targets, at a beam power of 20 kW. These targets could be milked at least three times, yielding nearly four curies of Ac-225. There is also a description of a method to reduce production of Ac-227 to values less than a few parts per million of the yield of Ac-225. The Monte Carlo code Fluka has been used to model the yields of Ra-225 and support the design concept to reduce the production of Ac-227. It has also been used to model the experimental results by Maslov et al. [https://doi.org/10.1134/S1066362206020184] to provide reasonable confidence in the cross-section value used by the code.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W. T. Diamond, C. K. Ross. 2021-01-01. Actinium-225 Production with an Electron Accelerator. https://doi.org/10.1063/5.0043509

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph