arXiv · 2104.12122
The beam exchange of a circular cooler ring with a ultrafast harmonic kicker
Abstract
In this paper, we describe a harmonic kicker system used in the beam exchange scheme for the Circulator Cooling Ring (CCR) of the Jefferson Lab Electron Ion Collider(JLEIC). By delivering an ultra-fast deflecting kick, a kicker directs electron bunches selectively in/out of the CCR without degrading the beam dynamics of the CCR optimized for ion beam cooling. We will discuss the design principle of the kicker system and demonstrate its performance with various numerical simulations. In particular, the degrading effects of realistic harmonic kicks on the beam dynamics, such as 3D kick field profiles interacting with the magnetized beam, is studied in detail with a scheme that keeps the cooling efficiency within allowable limits.
Explore related subjects
Keep this discovery
Gunn Tae Park, Jiquan Guo, Shaoheng Wang, Robert A. Rimmer, Haipeng Wang. 2021-04-25. The beam exchange of a circular cooler ring with a ultrafast harmonic kicker. https://doi.org/10.1103/physrevaccelbeams.24.061002
Cite the original work for its findings. Save a collection to share your selection of sources.