Avancee-1 Mission and SaDoD Method: LiDAR-based stimulated atomic disintegration of space debris (SaDoD) using Optical Neural Networks

Abstract

The surface degradation of satellites in Low Earth Orbit (LEO) is affected by Atomic Oxygen (AO) and varies depending on the spacecraft orbital parameters. Atomic oxygen initiates several chemical and physical reactions with materials and produces erosion and self-disintegration of the debris at high energy. This paper discusses Avancee-1 Mission, LiDAR-based space debris removal using Optical Neural Networks (ONN) to optimize debris detection and mission accuracy. The SaDoD Method is a Stimulated Atomic Disintegration of Orbital Debris, which in this case has been achieved using LiDAR technology and Optical Neural Networks. We propose Optical Neural Network algorithms with a high ability of image detection and classification. The results show that orbital debris has a higher chance of disintegration when the laser beam is coming from Geostationary Orbit (GEO) satellites and in the presence of high solar activities. This paper proposes a LiDAR-based space debris removal method depending on the variation of atomic oxygen erosion with orbital parameters and solar energy levels. The results obtained show that orbital debris undergoes the most intense degradation at low altitudes and higher temperatures. The satellites in GEO use Optical Neural Network algorithms for object detection before sending the laser beams to achieve self-disintegration. The SaDoD Method can be implemented with other techniques, but especially for the Avancee-1 Mission, the SaDoD was implemented with LiDAR technologies and Optical Neural Network algorithms.

Explore related subjects

Keep this discovery

BibTeXRIS

Manuel Ntumba, Saurabh Gore. 2021-05-27. Avancee-1 Mission and SaDoD Method: LiDAR-based stimulated atomic disintegration of space debris (SaDoD) using Optical Neural Networks. https://doi.org/10.13140/rg.2.2.34878.82240

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det