SearcharxivSearch

arXiv · 2106.09546

RTP Pockels Cell with Nanometer-Level Position Control

Abstract

MOLLER is a future experiment designed to measure parity violation in Moller scattering to extremely high precision. MOLLER will measure the right-left scattering differential cross-section parity-violating asymmetry APV , in the elastic scattering of polarized electrons off an unpolarized LH2 target to extreme ppb precision. To make this measurement, the polarized electron source, generated with a circularly polarized laser beam, must have the ability to switch quickly between right and left helicity polarization states. The polarized source must also maintain minimal right-left helicity correlated beam asymmetries, including energy changes, position changes, intensity changes, or spot-size changes. These requirements can be met with appropriate choice and design of the Pockels cell used to generate the circularly polarized light. Rubidium Titanyl Phosphate (RTP) has been used in recent years for ultra-fast Pockels cell switches due to its lack of piezo-electric resonances at frequencies up to several hundred MHz. However, crystal non-uniformity in this material leads to poorer extinction ratios than in commonly used KD*P Pockels cells when used in hald-wave configuration. It leads to voltage dependent beam steering when used in quarter-wave configuration. Here we present an innovative RTP Pockels cell design which uses electric field gradients to counteract crystal non-uniformities and control beam steering down to the nm-level. We demonstrate this RTP Pockels cell design is capable of producing precisely controlled polarized electron beam at Jefferson Laboratory, a national accelerator facility, for current experiments, including the recent PREX II measurement, as well as the future MOLLER experiment.

Explore related subjects

Keep this discovery

BibTeXRIS

Caryn Palatchi, Kent Paschke. 2021-06-15. RTP Pockels Cell with Nanometer-Level Position Control. https://arxiv.org/abs/2106.09546

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det