SearcharxivSearch

arXiv · 2106.14302

Non-destructive interrogation of nuclear waste barrels through muon tomography: A Monte Carlo study based on dual-parameter analysis via GEANT4 simulations

Abstract

In this study, we employ the Monte Carlo simulations by using the GEANT4 code to demonstrate the capability of muon tomography based on the dual-parameter analysis in the examination of the nuclear waste barrels. Our current hodoscope setup consists of three top and three bottom plastic scintillators made of polyvinyl toluene with the thickness of 0.4 cm, and the composite target material is a cylindrical nuclear waste drum with the height of 96 cm and the radius of 29.6 cm where the outermost layer is stainless steel with the lateral thickness of 3.2 cm and the filling material is ordinary concrete that encapsulates the nuclear materials of dimensions 20$\times$20$\times$20 cm$^{3}$. By simulating with a narrow planar muon beam of 1$\times$1 cm$^{2}$ over the uniform energy interval between 0.1 and 8 GeV, we determine the variation of the average scattering angle together with the standard deviation by utilizing a 0.5-GeV bin length, the counts of the scattering angle by using a 1-mrad step, and the number of the absorption events for the five prevalent nuclear materials starting from cobalt and ending in plutonium. Via the duo-parametric analysis that is founded on the scattering angle as well as the absorption in the present study, we show that the presence of the nuclear materials in the waste barrels is numerically visible in comparison with the concrete-filled waste drum without any nuclear material, and the muon tomography is capable of distinguishing these nuclear materials by coupling the information about the scattering angle and the number of absorption in the cases where one of these two parameters yields strong similarity for certain nuclear materials.

Explore related subjects

Keep this discovery

BibTeXRIS

Ahmet Ilker Topuz, Madis Kiisk, Andrea Giammanco. 2021-06-27. Non-destructive interrogation of nuclear waste barrels through muon tomography: A Monte Carlo study based on dual-parameter analysis via GEANT4 simulations. https://doi.org/10.1088/1748-0221/17/12/p12005

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det