SearcharxivSearch

arXiv · 2109.10518

Effect of passive metallic layers on muon energy estimation by means of deflection angle for muon scattering tomography: A comparative study based on GEANT4 simulations

Abstract

In the tomographic configurations based on the muon scattering, the angular variation with respect to the kinetic energy indirectly brings forth the ability to coarsely predict the kinetic energy by using the deflection angle owing to the detector layers. Nevertheless, the angular deviation due to the detector components is expected to be minuscule in addition to a relatively high uncertainty in the case of the plastic scintillators. In the present study, we contrast our current tomographic prototype, which consists of the detector layers manufactured from polyvinyl toluene besides a detector accuracy of 1 mrad, with an alternative hodoscope scheme containing stainless steel layers by aiming to investigate the three-group energy structure. Initially, we determine the average deflection angles together with the corresponding standard deviations for our present setup as well as for the alternative scheme by means of the GEANT4 simulations. In the second place, we express a brace of misclassification probabilities founded on the standard deviations where the first procedure assumes a linear finite approximation, whereas the latter approach rests on a positively defined modified Gaussian distribution. Upon our simulation results, we demonstrate that the introduced stainless steel layers in the proposed hodoscope setup do not only serve to augment the average deflection angles, but they also diminish the misclassification probabilities, therewith reducing the classification uncertainty apart from an improved detection performance.

Explore related subjects

Keep this discovery

BibTeXRIS

Ahmet Ilker Topuz, Madis Kiisk, Andrea Giammanco, Mart Magi. 2021-09-22. Effect of passive metallic layers on muon energy estimation by means of deflection angle for muon scattering tomography: A comparative study based on GEANT4 simulations. https://doi.org/10.1088/1748-0221/17/02/c02008

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det