arXiv · 2111.10863
Atomic force microscopy calibration of standing surface acoustic wave amplitudes
Abstract
Atomic force microscopy is an important tool for characterizing surface acoustic waves, in particular for high frequencies, where the wavelength is too short to be resolved by laser interferometry. A caveat is, that the cantilever deflection is not equal to the amplitude of the surface acoustic wave. We show, that the energy transfer from the moving surface to the cantilever instead leads to a deflection exceeding the surface modulation. We present a method for an accurate calibration of surface acoustic wave amplitudes based on comparing force-curve measurements with the equation of motion of a driven cantilever. We demonstrate our method for a standing surface acoustic wave on a GaAs crystal confined in a focusing cavity with a resonance frequency near 3 GHz.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Jan Hellemann, Filipp Müller, Madeleine Msall, Paulo V. Santos, Stefan Ludwig. 2021-11-21. Atomic force microscopy calibration of standing surface acoustic wave amplitudes. https://doi.org/10.1103/physrevapplied.17.044024
Cite the original work for its findings. Save a collection to share your selection of sources.