SearcharxivSearch

arXiv · 2112.00163

Optimization of FLASH Proton Beams Using a Track-Repeating Algorithm

Abstract

Methods: A phase space file in a plane at 202 mm downstream of the beam exit window is generated through tuning parameters to match FDC results with measured or MCNPX Monte Carlo-simulated integrated depth-dose distribution (IDD) and lateral dose profiles. To spread out the Bragg peak, widen the beam and reduce the penumbra, a ridge filter (RF), a high-Z material scatterer and a collimator with compensator are inserted in the beam path and their shapes and sizes have been optimized. The FDC calculations are validated by comparing Geant4 Monte Carlo simulations. In addition, a set of algorithms to automatically choose the optimum dimensions of the beam shaping elements is developed and tested using the same beams. At the last part, dose rates for optimized beams were estimated by scaling their dose distributions to that of their original beams. Results: The optimized 86.4 MeV beam had an 8.5 mm wide spread-out Bragg peak (SOBP) (proximal 90% to distal 90% of the maximum dose), 14.5 mm, 12.0 mm and 11.0 lateral widths with dose above 50%, 80% and 90% respectively and a 2.5 mm penumbra from 80% to 20% in the lateral profile for the energy. The 159.5 MeV beam had a SOBP of 39.0 mm and the lateral widths with dose above 50%, 80% and 90% of 20.5 mm, 15.0 and 12.5 mm when the source to surface distance (SSD) was 550 mm. Wider lateral widths was obtained with increased SSD. The FDC calculations had passing rates higher than 96% using 3mm/3% as the gamma-index criterion comparing with Geant4 simulations for both energies. The set of automatic algorithms can choose the proper dimensions for the high-density scatterer, RF, collimator and compensator efficiently. And the optimized 159.5 MeV beam with different SDDs had entrance dose rate higher than 40 Gy/s if the entrance dose rate of the original beam was 150 Gy/s.

Explore related subjects

Keep this discovery

BibTeXRIS

Qianxia Wang, Uwe Titt, Radhe Mohan, Fada Guan, Yao Zhao, Ming Yang, Pablo Yepes. 2021-11-30. Optimization of FLASH Proton Beams Using a Track-Repeating Algorithm. https://doi.org/10.1002/mp.15849

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph