SearcharxivSearch

arXiv · 2112.10704

Design and Characterization of an Optically-Segmented Single Volume Scatter Camera Module

Abstract

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for nuclear non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. We report on the design, construction, and calibration of one module of a new prototype. The module includes 16 EJ-204 organic plastic scintillating bars individually wrapped in Teflon tape, each measuring 0.5 cm$\times$0.5 cm$\times$20 cm. The scintillator array is coupled to two custom Silicon Photomultiplier (SiPM) boards consisting of a 2$\times$8 array of SensL J-Series-60035 Silicon Photomultipliers, which are read out by a custom 16 channel DRS-4 based digitizer board. The electrical crosstalk between SiPMs within the electronics chain is measured as 0.76% $\pm$ 0.11% among all 16 channels. We report the detector response of one module including interaction position, time, and energy, using two different optical coupling materials: EJ-560 silicone rubber optical coupling pads and EJ-550 optical coupling grease. We present results in terms of the overall mean and standard deviation of the z-position reconstruction and interaction time resolutions for all 16 bars in the module. We observed the z-position resolution for gamma interactions in the 0.3 MeVee to 0.4 MeVee range to be 2.24 cm$\pm$1.10 cm and 1.45 cm$\pm$0.19 cm for silicone optical coupling pad and optical grease, respectively. The observed interaction time resolution is 265 ps$\pm$29 ps and 235 ps$\pm$10 ps for silicone optical coupling pad and optical grease, respectively.

Explore related subjects

Keep this discovery

BibTeXRIS

Kevin Keefe, Hassam Alhajaji, Erik Brubaker, Andrew Druetzler, Aline Galindo-Tellez, John Learned, Paul Maggi, Juan J. Manfredi, Kurtis Nishimura, Bejamin Pinto Souza, John Steele, Melinda Sweany, Eric Takahashi. 2021-12-20. Design and Characterization of an Optically-Segmented Single Volume Scatter Camera Module. https://doi.org/10.1109/tns.2022.3172002

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det