SearcharxivSearch

arXiv · 2204.08527

A simple mathematical model of cyclic hypoxia and its impact on hypofractionated radiotherapy

Abstract

There is evidence that the population of cells that experience fluctuating oxygen levels are more radioresistant than chronically hypoxic ones and hence, this population may determine radiotherapy (RT) response, in particular for hypofractionated RT, where reoxygenation may not be as prominent. A considerable effort has been devoted to examining the impact of hypoxia on hypofractionated RT; however, much less attention has been paid to cyclic hypoxia specifically and the role its kinetics may play in determining the efficacy of these treatments. Here, a simple mathematical model of cyclic hypoxia and fractionation effects was worked out to quantify this. Cancer clonogen survival fraction was estimated using the linear quadratic model, modified to account for oxygen enhancement effects and inter-fraction tissue oxygen kinetics. The resulting survival fraction formula was used to derive an expression for the iso-survival biologically effective dose, $\bedeff$. These were computed for some common extra-cranial hypofractionated radiotherapy regimens. Using relevant literature parameter values, inter-fraction fluctuations in oxygenation were found to result in an added 1-2 logs of clonogen survival fraction in going from five fractions to one for the same nominal biologically effective dose. $\bedeff$'s for most ultra-hypofractionated (five or fewer fractions) regimens in a given tumour site are similar in magnitude, suggesting iso-efficacy for common fractionation schedules. Although significant, the loss of cell-killing with increasing hypofractionation is not nearly as large as previous estimates based on the assumption of complete reoxygenation between fractions. Most ultra-hypofractionated regimens currently in place offer sufficiently high doses to counter this loss of cell killing, although care should be taken in implementing single-fraction regimens.

Explore related subjects

Keep this discovery

BibTeXRIS

Edward Taylor. 2022-04-18. A simple mathematical model of cyclic hypoxia and its impact on hypofractionated radiotherapy. https://doi.org/10.1002/mp.16200

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph