SearcharxivSearch

arXiv · 2204.14064

An Integrated Air Quality Monitoring System for COVID-19 Virus Detection

Abstract

The pandemic of coronavirus disease 2019 (COVID-19) caused by syndrome-coronavirus-2 (SARS-CoV-2) has been found rapid and large-scale diagnosis to spread across the communities. The risk of infectious airborne aerosol transmission has been an area of increasing concern. In this regard, a selective optic detection of SARS-CoV-2 aerosol is highly desirable, which can actively collect the surrounding air samples and provide real-time feedbacks to users. In this work, we developed an integrated Air Quality Monitoring System (iAQMS) that enables real-time SARS-CoV-2 aerosol detection with high sensitivity. The detection device, inspired by localized surface plasmon resonance (LSPR), was designed to measure the intensity changes of light going through our biochips in which gold nanoparticles (AuNP) combined with antibodies were exposed to airflow containing virus aerosols. We found that the variation of the measured photocurrent after 350 seconds of exposure to virus aerosols is a function of virus particle concentrations. By incorporating the air collection device and the optic detection device into a handheld sized device that can communicate with a smart-phone through Bluetooth serial, we demonstrate real-time and sensitive detection of SARS-CoV-2 virus aerosols with a concentration dynamic range of 0.00001 - 0.1 pfu/uL. Because of its sensitivity and reliability, our device can also be used for detection of other virus aerosols by simply switching the antibodies combined to the AuNP in the biochips.

Explore related subjects

Keep this discovery

BibTeXRIS

Hanzhi Yang. 2022-04-23. An Integrated Air Quality Monitoring System for COVID-19 Virus Detection. https://arxiv.org/abs/2204.14064

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Multiscale retinal flow on a spherical cap of varying aperture

Modelling retinal haemodynamics is crucial for understanding retinal microcirculation but is computationally demanding because it involves coupling between the vasculature and surrounding tissue across multiple scales. This computational burden has been substantially alleviated by a recent analytic solution on the planar disc that enables lumping the capillary bed and surrounding tissue into an effective resistor. However, that formulation treats the retina as a flat surface, whereas the retina is a curved surface with a finite anterior aperture. In this work, we develop a nontrivial and physiologically necessary extension to spherical-cap tissue domains with varying apertures, where surface curvature and finite-aperture boundaries complicate solving coupled Darcy equations on a curved manifold. Using a stereographic projection and a decoupling transformation, we derive an analytic solution for the capillary-tissue system on the spherical cap that represents flow in both the capillary bed and interstitial tissue more realistically while retaining the efficient resistor formulation, a key advantage of the planar-disc formulation. This solution is coupled to one-dimensional (1D) arteriolar and venular flows to obtain a multiscale description of retinal haemodynamics. Using a vasculature model designed to capture retinal vascular features, we show that the multiscale model's predictions are consistent with experimental data. We further explore aperture effects using both a fixed hemispherical vasculature and aperture-dependent vasculature. The aperture affects retinal haemodynamics mainly through changes in the constructed vasculature itself, whereas the surface-averaged pressures and relative terminal flow distributions remain nearly unchanged. This framework provides a foundation for studying retinal pathophysiology on more anatomically realistic domains.

physics.bio-ph

Double-well potentials and crucial estimations in nonlinear dynamics of microtubules

In the present work, we study the two-component model of microtubules, the basic components of the eukaryotic cytoskeleton. We introduce a couple of estimations, which tremendously simplified the model. The paper is devoted to tangential oscillations of dimers, but we explain that the model can explain the radial oscillations as well. Finally, we study the stability of all solutions of differential equations, describing the dynamics of the microtubules.

physics.bio-ph

A thermodynamically consistent framework for finite growth of multi-constituent mixtures with application to tumor growth

Biological tissues grow by continuously producing, transporting, and reorganizing multiple interacting constituents. These processes are intrinsically coupled to finite deformation and residual stress. Existing models typically capture either finite growth kinematics or multi-constituent transport, but rarely both within a thermodynamically consistent setting. In particular, existing approaches do not consistently link the volume created by finite growth to the mass produced for each individual constituent. In this work, we develop a general continuum framework that unifies finite growth kinematics and multiphase mixture theory for fully saturated multi-constituent mixtures containing an arbitrary number of dilute dissolved solutes. Formulated in a solid-skeleton-based description, the framework rests on constituent-wise balance laws and a free-energy dissipation principle, from which thermodynamically admissible constitutive closures are derived for all mass-exchange, transport, reaction, and growth processes. The central novelty of the framework is a coupling between growth-induced volume creation and constituent mass production, expressed through volume accumulation fractions that distribute the newly created volume among the constituents while preserving saturation. We cast the resulting model in a total Lagrangian mixed weak form and specialize the general theory to a four-constituent, two-solute model of avascular tumor growth that couples nutrient transport, waste production, phenotype transitions between proliferative, hypoxic, and necrotic cells, volume growth, elastic deformation, and growth-induced residual stress. The model is implemented within a finite element setting and its capabilities are demonstrated on representative benchmark problems.

physics.bio-ph