SearcharxivSearch

arXiv · 2204.14210

The Analysis of a Proposed Experiment to Measure the Speed of Gravity in Short Distances

Abstract

In order to investigate the speed of gravitational signals travelling in air or through a different medium two experiments were designed. One of the experiments contains 2 masses rotating at very high speed and in the other experiment a sapphire bar will vibrate, in both cases they will emit a periodic tidal gravitational signal and one sapphire device that behaves as a detector, which are suspended in vacuum and cooled down to 4.2 K will act as a detector. The vibrational amplitude of the sapphire detector device is measured by an microwave signal with ultralow phase-noise that uses resonance in the whispering gallery modes inside the detector device. Sapphire has a quite high mechanical Q and electrical Q which implies a very narrow detection band thus reducing the detection sensitivity. A new detector shape for the detector device is presented in this work, yielding a detection band of about half of the device vibrational frequency. With the aid of a Finite Element Program the normal mode frequencies of the detector can be calculated with high precision. The results show a similar expected sensitivity between the two experimental setup, but the experiment with the vibration masses is more stable in frequency then it is chosen for the experimental setup to measure the speed of gravity in short distances. Then a more precise analysis is made with this experiment reaching a signal-noise ratio of 10 at a frequency of 5000 Hz.

Explore related subjects

Keep this discovery

BibTeXRIS

Carlos Frajuca, Fabio da Silva Bortoli, Nadja Simão Magalhaes. 2022-04-29. The Analysis of a Proposed Experiment to Measure the Speed of Gravity in Short Distances. https://arxiv.org/abs/2204.14210

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det