arXiv · 2205.01378
Complex-order Reset Control System
Abstract
According to the well-known loop shaping method for the design of controllers, the performance of the controllers in terms of step response, steady-state disturbance rejection and noise attenuation and robustness can be improved by increasing the gain at lower frequencies and decreasing it at higher frequencies and increasing the phase margin as much as possible. However, the inherent properties of linear controllers, the Bode's phase-gain relation, create a limitation. In theory, a complex-order transfer function can break the Bode's gain-phase relation; however, such transfer function cannot be directly implemented and should be approximated. This paper proposes a reset element and a tuning method to approximate a Complex-Order Controller (CLOC) and, through a simulation example, shows the benefits of using such a controller.
Explore related subjects
Keep this discovery
Nima Karbasizadeh, S. Hassan HosseinNia. 2022-05-03. Complex-order Reset Control System. https://doi.org/10.1109/aim52237.2022.9863350
Cite the original work for its findings. Save a collection to share your selection of sources.