SearcharxivSearch

arXiv · 2209.02768

Prospectively accelerated dynamic speech MRI at 3 Tesla using a self-navigated spiral based manifold regularized scheme

Abstract

This work proposes a self-navigated variable density spiral(VDS) based manifold regularization scheme to prospectively improve dynamic speech MRI at 3T. Short readout 1.3ms spirals were used to minimize off-resonance. A custom 16-channel speech coil was used for improved parallel imaging of vocal tract. The manifold model leveraged similarities between frames sharing similar speech postures without explicit motion binning. The self-navigating capability of VDS was leveraged to learn the Laplacian matrix of the manifold. Reconstruction was posed as a SENSE-based non-local soft weighted temporal regularization scheme. Our approach was compared against view-sharing, low-rank, finite difference, extra-dimension-based sparsity reconstruction constraints. Under-sampling experiments were conducted on five volunteers performing repetitive and arbitrary speaking tasks at different speaking rates. Quantitative evaluation in terms of mean square error over moving edges were performed in a retrospectively under-sampled data. For prospective under-sampling, blinded image quality evaluation in the categories of alias artifacts, spatial blurring, and temporal blurring were performed by three voice research experts. Region of interest analysis at articulator boundaries were performed to assess articulatory motion. Our scheme provided improved reconstruction over the others. With prospective under-sampling, a spatial resolution of 2.4mm2/pixel and a temporal resolution of 17.4 ms/frame for single slice imaging, and 52.2 ms/frame for 3-slice imaging were achieved. We demonstrated implicit motion binning by analyzing the mechanics of the Laplacian matrix. Our method demonstrated superior image quality scores in reducing spatial and temporal blurring. While it exhibited faint alias artifacts similar to temporal finite-difference, it provided statistically significant improvements over remaining constraints.

Explore related subjects

Keep this discovery

BibTeXRIS

Rushdi Zahid Rusho, Abdul Haseeb Ahmed, Stanley Kruger, Wahidul Alam, David Meyer, David Howard, Brad Story, Mathews Jacob, Sajan Goud Lingala. 2022-09-06. Prospectively accelerated dynamic speech MRI at 3 Tesla using a self-navigated spiral based manifold regularized scheme. https://arxiv.org/abs/2209.02768

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Exponential Pixelating Integral transform with dual fractal features for enhanced chest X-ray abnormality detection

The heightened prevalence of respiratory disorders, particularly exacerbated by a significant upswing in fatalities due to the novel coronavirus, underscores the critical need for early detection and timely intervention. This imperative is paramount, possessing the potential to profoundly impact and safeguard numerous lives. Medically, chest radiography stands out as an essential and economically viable medical imaging approach for diagnosing and assessing the severity of diverse Respiratory Disorders. However, their detection in Chest X-Rays is a cumbersome task even for well-trained radiologists owing to low contrast issues, overlapping of the tissue structures, subjective variability, and the presence of noise. To address these issues, a novel analytical model termed Exponential Pixelating Integral is introduced for the automatic detection of infections in Chest X-Rays in this work. Initially, the presented Exponential Pixelating Integral enhances the pixel intensities to overcome the low-contrast issues that are then polar-transformed followed by their representation using the locally invariant Mandelbrot and Julia fractal geometries for effective distinction of structural features. The collated features labeled Exponential Pixelating Integral with dually characterized fractal features are then classified by the non-parametric multivariate adaptive regression splines to establish an ensemble model between each pair of classes for effective diagnosis of diverse diseases. Rigorous analysis of the proposed classification framework on large medical benchmarked datasets showcases its superiority over its peers by registering a higher classification accuracy and F1 scores ranging from 98.46 to 99.45% and 96.53-98.10% respectively, making it a precise and interpretable automated system for diagnosing respiratory disorders.

eess.IV

Myocardial Strain Drift Correction in Deep Learning Based Ultrasound Tracking

Myocardial strain from echocardiography is a key biomarker for cardiac function. Recent deep learning methods show strong performance for myocardial motion tracking but often lack physiological constraints, leading to temporal drift across the cardiac cycle. Consequently, tracked points may not return to their relative initial positions at the end of each cardiac cycle, producing inaccurate strain estimates and even divergence in some cases. We propose a deep learning framework that compensates for drift during myocardial tracking. We extend a state-of-the-art echocardiographic tracking method (TAS-Net) with persistent memory tokens that share information across sliding windows over full cardiac cycles. A teacher-student fine-tuning strategy on real echocardiographic data then enforces physiologically consistent cyclic motion while preserving tracking accuracy. Experiments show reduced global and regional strain drift, improved agreement with clinical references, and better test-retest reproducibility, supporting more reliable myocardial strain estimation in clinical practice.

eess.IV

Morphological Decoupling-Based Skeletal Classification for Clinical Assessment of Malocclusion

Malocclusion skeletal grading is a fundamental task in orthodontics, critical for diagnosis and treatment planning. Traditionally, cone-beam computed tomography (CBCT) is used for visual measurement, and the reconstructed lateral cephalograms are handed over to expert dentists for diagnosis. However, manual review is time-consuming, labor-intensive, and subject to inter-operator variability. Therefore, an automatic CBCT-based system is needed for reliable malocclusion skeletal grading. In this case, we develop TeethGNN, a novel graph-based framework designed to combine CBCT image features with morphological information for accurate and efficient malocclusion grading. TeethGNN utilizes a decoupled learnable decoder to directly predict key morphological indicators from CBCT images, eliminating the need for manual measurements. These morphological features are then fused with image features using a graph neural network (GNN), which effectively models the relationships between the modalities. To further enhance robustness and calibration, we introduce a collaborative calibration strategy. This strategy combines multi-scale graph adversarial perturbation for explicit calibration and nonlinear topological graph calibration for implicit confidence adjustment. Extensive experiments and ablation studies on our collected clinical dataset demonstrate that our malocclusion measurement system achieves 77.08\% in accuracy and 89.61\% in AUC, outperforming the compared state-of-the-art methods. These results validate the effectiveness of graph-based multimodal fusion and collaborative calibration in improving malocclusion grading performance. Our system shows strong potential for advancing computer-aided orthodontic diagnosis, providing an accurate and reliable solution for vision-based clinical measurement and diagnosis.

eess.IV