SearcharxivSearch

arXiv · 2212.07644

Ultraviolet Raman Spectroscopy for Remote Detection of Chlorine Gas

Abstract

As a primary material frequently used in industry, chlorine is relatively easy to obtain and available even in large quantities. Despite its high toxicity, molecular chlorine is readily available since it is an essential educt in the chemical industry. Over the past decades, numerous accidents involving injured and dead victims have occurred. Furthermore, it was already misused as a warfare agent at the beginning of the last century with still reported attacks. Early detection, localization, and monitoring of sources and cloud movements are essential for protecting stationary facilities, mobile operations, and the public. In contrast to most chemical hazardous materials, where it is possible to detect them by vibrational spectroscopic methods (e.\,g., passive hyper-spectral absorption technologies in the infrared), halogens are inactive to infrared absorption. Raman-based technologies rely on changes in the polarizability of the molecule and provide vibrational-spectroscopic access to such diatomic molecules and therefore close the gap in infrared detection capabilities. Here we present a straightforward approach for a standoff Raman detector in a backscattering configuration. This paper uses a simplified model to discuss optimum excitation wavelengths in achievable detection ranges. We validate the model by spontaneous (vibrational) Raman spectroscopic measurements between 20 and 60~m standoff distance. We also briefly discuss detection performances and technical and physical aspects as prospects of system design.

Explore related subjects

Keep this discovery

BibTeXRIS

Arne Walter, Frank Wilsenack, Thomas Wolf, Frank Duschek. 2022-12-15. Ultraviolet Raman Spectroscopy for Remote Detection of Chlorine Gas. https://doi.org/10.1088/1748-0221/18/05/c05008

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det