arXiv · 2212.14771
Development of a Self-Calibrated Motion Capture System by Nonlinear Trilateration of Multiple Kinects v2
Abstract
In this paper, a Kinect-based distributed and real-time motion capture system is developed. A trigonometric method is applied to calculate the relative position of Kinect v2 sensors with a calibration wand and register the sensors' positions automatically. By combining results from multiple sensors with a nonlinear least square method, the accuracy of the motion capture is optimized. Moreover, to exclude inaccurate results from sensors, a computational geometry is applied in the occlusion approach, which discovers occluded joint data. The synchronization approach is based on an NTP protocol that synchronizes the time between the clocks of a server and clients dynamically, ensuring that the proposed system is a real-time system. Experiments for validating the proposed system are conducted from the perspective of calibration, occlusion, accuracy, and efficiency. Furthermore, to demonstrate the practical performance of our system, a comparison of previously developed motion capture systems (the linear trilateration approach and the geometric trilateration approach) with the benchmark OptiTrack system is conducted, therein showing that the accuracy of our proposed system is $38.3\%$ and 24.1% better than the two aforementioned trilateration systems, respectively.
Explore related subjects
Keep this discovery
Bowen Yang, Haiwei Dong, Abdulmotaleb El Saddik. 2022-12-25. Development of a Self-Calibrated Motion Capture System by Nonlinear Trilateration of Multiple Kinects v2. https://doi.org/10.1109/jsen.2017.2671420
Cite the original work for its findings. Save a collection to share your selection of sources.