SearcharxivSearch

arXiv · 2303.15314

Development of a thorium coating on an aluminium substrate by using electrodeposition method and alpha spectroscopy

Abstract

A thin coating of thorium on aluminium substrates with the areal density of 110 to 130 $\mu g/cm^2$ is developed over a circular area of 22 mm diameter by using the electrodeposition method. An electrodeposition system is fabricated to consist of three components; an anode made of a platinum mesh, a cylindrical-shape vessel to contain the thorium solution, and a cathode in the form of a circular aluminium plate. The aluminium plate is mounted horizontally, and the platinum mesh is connected to an axial rod of an electric motor, mounted vertically and normal to the plane of the aluminium. The electrolyte solution is prepared by dissolving a known-weight thorium nitrate powder in 0.8 M HNO3 and isopropanol. The system is operated either in constant voltage (CV) or constant current (CC) mode. Under the electric field between the anode and cathode, thorium ions were deposited on the aluminium substrate mounted on the cathode. In the CV mode at 320, 360, and 400 V and in the CC mode at 15 mA, thorium films were formed over a circular area of the aluminium substrate. The areal density of thorium coating was measured by detecting emitted alpha particles. The areal density of thorium varied from 80 to 130 $\mu g/cm^2$ by changing the deposition time from 10 to 60 min. The results from the CV mode and CC mode are compared, and the radial dependence in the measured areal density is discussed for different modes of the electric field. The developed thorium coatings are to be used in the in-house development of particle detectors, fast neutron converters, targets for thorium fission experiments, and other purposes.

Explore related subjects

Keep this discovery

BibTeXRIS

Dal-Ho Moon, Vivek Chavan, Vasant Bhoraskar, Yeong Hoon Jeong, Jung Ho Park, Su-Jeong Suh, Seung-Woo Hong. 2023-03-11. Development of a thorium coating on an aluminium substrate by using electrodeposition method and alpha spectroscopy. https://arxiv.org/abs/2303.15314

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det