arXiv · 2306.07066
Indirect Measurement of Switch Terms of a Vector Network Analyzer with Reciprocal Devices
Abstract
This paper presents an indirect method for measuring the switch terms of a vector network analyzer (VNA) using at least three reciprocal devices, which do not need to be characterized beforehand. This method is particularly suitable for VNAs that use a three-sampler architecture, which allows for applying first-tier calibration methods based on the error box model. The proposed method was experimentally verified by comparing directly and indirectly measured switch terms and performing a multiline thru-reflect-line (TRL) calibration.
Explore related subjects
Keep this discovery
Ziad Hatab, Michael Ernst Gadringer, Wolfgang Bösch. 2023-06-12. Indirect Measurement of Switch Terms of a Vector Network Analyzer with Reciprocal Devices. https://doi.org/10.1109/lmwt.2023.3311032
Cite the original work for its findings. Save a collection to share your selection of sources.