2D antiscatter grid and scatter sampling based CBCT pipeline for image guided radiation therapy

Abstract

Poor tissue visualization and quantitative accuracy in CBCT is a major barrier in expanding the role of CBCT imaging from target localization to quantitative treatment monitoring and plan adaptations in radiation therapy sessions. To further improve image quality in CBCT, 2D antiscatter grid based scatter rejection was combined with a raw data processing pipeline and iterative image reconstruction. The culmination of these steps was referred as quantitative CBCT, qCBCT. qCBCT data processing steps include 2D antiscatter grid implementation, measurement based residual scatter, image lag, and beam hardening correction for offset detector geometry CBCT with a bow tie filter. Images were reconstructed with iterative image reconstruction to reduce image noise. To evaluate image quality, qCBCT acquisitions were performed using a variety of phantoms to investigate the effect of object size and its composition on image quality. qCBCT image quality was benchmarked against clinical CBCT and MDCT images. Addition of image lag and beam hardening correction to scatter suppression reduced HU degradation in qCBCT by 10 HU and 40 HU, respectively. When compared to gold standard MDCT, mean HU errors in qCBCT and clinical CBCT were 10 HU and 27 HU, respectively. HU inaccuracy due to change in phantom size was 22 HU and 85 HU in qCBCT and clinical CBCT images, respectively. With iterative reconstruction, contrast to noise ratio improved by a factor of 1.25 when compared to clinical CBCT protocols. Robust artifact and noise suppression in qCBCT images can reduce the image quality gap between CBCT and MDCT, improving the promise of qCBCT in fulfilling the tasks that demand high quantitative accuracy, such as CBCT based dose calculations and treatment response assessment in image guided radiation therapy.

Explore related subjects

Keep this discovery

BibTeXRIS

Farhang Bayat, Dan Ruan, Moyed Miften, Cem Altunbas. 2023-08-17. 2D antiscatter grid and scatter sampling based CBCT pipeline for image guided radiation therapy. https://arxiv.org/abs/2308.09095

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph