arXiv · 2308.16607
Comparative analysis of recirculating and collimating cesium ovens
Abstract
We have performed a study of several cesium oven designs. A comparison between recirculating (or sticking-wall) or collimating (or reemitting-wall) ovens is made in order to extract the most efficient design in terms of beam brightness. Unfortunately, non-reproducible behaviors have been observed, and the most often observed output flux is similar to the sticking-wall case, which is the lowest theoretical value of the two cases, with a beam brightness close to $10^{18}$ at.sr$^{-1}$.s$^{-1}$.cm$^{-2}$. The reason of this universally observed behavior is unclear despite having tested several materials for the collimating tube. Conclusion on possible improved design based on sticking of cesium on several (un)cleaned surface is given.
Explore related subjects
Keep this discovery
Raphaël Hahn, Thomas Battard, Oscar Boucher, Yan J. Picard, Hans Lignier, Daniel Comparat, Nolwenn-Amandine Keriel, Colin Lopez, Emanuel Oswald, Morgan Reveillard, Matthieu Viteau. 2023-08-31. Comparative analysis of recirculating and collimating cesium ovens. https://doi.org/10.1063/5.0085838
Cite the original work for its findings. Save a collection to share your selection of sources.