SearcharxivSearch

arXiv · 2312.06078

Comparison and analysis of methods for measuring the spin transverse relaxation time of rubidium atomic vapor

Abstract

The spin transverse relaxation time (T_2) of atoms is an important indicator for precision measurement. Several methods have been proposed to characterize the T_2 of atoms. In this paper, the T_2 of rubidium (Rb) atomic vapor in the same cell was measured using four measuring methods, namely spin noise spectrum signal fitting, improved free induction decay (FID) signal fitting, w_m-broadening fitting, and magnetic resonance broadening fitting. Meanwhile, the T_2 of five different types of Rb atomic vapor cells were measured and characterized. A comparative analysis visualizes the characteristics of the different measuring methods and the effects of buffer gas on T_2 of Rb. We theoretically and experimentally analyzed the applicability of the different methods, and then demonstrated that the improved FID signal fitting method provides the most accurate measurement because of the clean environment in which the measurements were taken. Furthermore, we demonstrated and qualitatively analyzed the relationship between the atomic number density and the T_2 of Rb. This work provides analytical insight in selecting atomic vapor cells, and may shed light on the improvement of the sensitivity of atomic magnetometers.

Explore related subjects

Keep this discovery

BibTeXRIS

Lulu Zhang, Ni Zhao, Yongbiao Yang, Junye Zhao, Jun He, Junmin Wang. 2023-12-11. Comparison and analysis of methods for measuring the spin transverse relaxation time of rubidium atomic vapor. https://arxiv.org/abs/2312.06078

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Delay-engineered dynamical phases in a programmable non-Markovian spin oscillator

Non-Markovian dynamics offer a new route towards engineering non-equilibrium matter, where memory and feedback act as programmable resources for controlling order in time. Here we report the realization of a non-Markovian spin oscillator in a hot vapour $^{129}$Xe-Cs co-magnetometer with programmable feedback delay and gain. By tuning these parameters, we observe a hierarchy of dynamical phases, including time-crystalline response, nonlinear bifurcations, and frequency-comb formation. The measured spectra and phase boundaries are captured by linear stability analysis of delayed Bloch equations, revealing these phenomena as different manifestations of the same memory-induced instability structure. These results establish time-delayed feedback as a powerful strategy for controlling non-equilibrium phases, enabling quantum sensing, frequency referencing, and synchronization within a single spin-based platform.

physics.atom-ph

Non-stick vacuum wall collisions with a laser-coolable molecule

Molecular species that are suitable for direct laser cooling are typically considered lost or destroyed if they collide with an ambient temperature vacuum wall. Here, we study surface collisions with aluminum monofluoride (AlF), a laser-coolable molecule that survives this process with unusually high probability. We detect the outgoing AlF molecules from a single wall collision via Doppler-sensitive laser-induced fluorescence spectroscopy, using incoming supersonic (pulsed) and thermochemical (continuous) molecular beams. The angular, velocity and rovibrational level distributions of the outgoing molecules show near-complete thermalisation to the wall in a single collision event. We determine an upper limit to the surface residence time of about 5$~\mu$s, and by monitoring the decay in density of pulses of molecules loaded into a small storage volume, we deduce the surface sticking probability for different materials. For a siloxane-coated metallic surface, the sticking probability of AlF is about 0.015, allowing us to accumulate molecules from the thermochemical source into an ambient temperature storage vessel at densities near $10^{8}~$cm$^{-3}$. This provides a route to compact, portable traps for neutral molecules.

physics.atom-ph

Kinetic modeling of molecular beam formation in a cryogenic buffer-gas cell

Cryogenic buffer-gas cells are widely used to produce cold molecular beams, but the microscopic dynamics governing beam formation remain challenging to model. Here we present fully kinetic simulations of a cryogenic buffer-gas cell using the Direct Simulation Monte Carlo method implemented in the PICLas framework, treating the buffer gas and ablated molecules within a single unified model. We capture characteristic features of cryogenic buffer-gas sources, including plume cooling, directed transport toward the aperture, and the formation of a slow molecular beam, while also resolving energy transfer from the hot ablation plume to the helium buffer gas that is inaccessible to existing approaches relying on the background-gas approximation. Our results demonstrate that fully kinetic simulations can provide detailed insights into buffer-gas cell dynamics and open a route toward a systematic optimization of such sources.

physics.atom-ph