SearcharxivSearch

arXiv · 2401.04231

Mapping Whole Exome Sequencing to In Vivo Imaging with Stereotactic Localization and Deep Learning

Abstract

This study presents a multi-faceted approach combining stereotactic biopsy with standard clinical open-craniotomy for sample collection, voxel-wise analysis of MR images, regression-based Generalized Additive Models (GAM), & whole-exome sequencing. This work aims to demonstrate the potential of machine learning algorithms to predict variations in cellular & molecular tumor characteristics. This retrospective study enrolled ten treatment-naive patients with radiologically confirmed glioma (5 WHO grade II, 5 WHO grade IV). Each patient underwent a multiparametric MR scan (T1W, T1W-CE, T2W, T2W-FLAIR, DWI) prior to surgery (27.9+/-34.0 days). During standard craniotomy procedure, at least 1 stereotactic biopsy was collected from each patient, with screenshots of the sample locations saved for spatial registration to pre-surgical MR data. Whole-exome sequencing was performed on flash-frozen tumor samples, prioritizing the signatures of five glioma-related genes: IDH1, TP53, EGFR, PIK3CA, & NF1. Regression was implemented with a GAM using a univariate shape function for each predictor. Standard receiver operating characteristic analyses were used to evaluate detection, with AUC (area under curve) calculated for each gene target & MR contrast combination. The mean AUC for the five gene targets & 31 MR contrast combinations was 0.75+/-0.11; individual AUCs were as high as 0.96 for both IDH1 & TP53 with T2W-FLAIR & ADC & 0.99 for EGFR with T2W & ADC. An average AUC of 0.85 across the five mutations was achieved using the combination of T1W, T2W-FLAIR, & ADC. These results suggest the possibility of predicting exome-wide mutation events from non-invasive, in vivo imaging by combining stereotactic localization of glioma samples & a semi-parametric deep learning method. This approach holds potential for refining targeted therapy by better addressing the genomic heterogeneity of glioma tumors.

Explore related subjects

Keep this discovery

BibTeXRIS

Mahsa Servati, Courtney N. Vaccaro, Emily E. Diller, Renata Pellegrino Da Silva, Fernanda Mafra, Sha Cao, Katherine B. Stanley, Aaron Cohen-Gadol, Jason G. Parker. 2024-01-08. Mapping Whole Exome Sequencing to In Vivo Imaging with Stereotactic Localization and Deep Learning. https://arxiv.org/abs/2401.04231

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph