Classical and Bayesian statistical methods for low-level metrology

Abstract

This document presents the statistical methods used to process low-level measurements in the presence of noise. These methods can be classical or Bayesian. The question is placed in the general framework of the problem of nuisance parameters, one of the canonical problems of statistical inference. By using a simple criterion proposed by Bolstad (2007), it is possible to define statistically significant results during a measurement process (act of measuring in the vocabulary of metrology). This result is similar for a classic paradigm (called ``frequentist'') or Bayesian: the presence of zero in the interval considered (confidence or credibility). It is shown that in the case of homoskedastic Gaussians, the commonly used results are found. The case of Poisson distributions is then considered. In the case of heteroscedastic Gaussians, which is that of radioactivity measurement, we can consider them as Poisson laws in the limit of large counts. The results are different from those commonly used, and in particular those from standards (ISO 11929). Their statistical performances, characterized by simulation, are better and are well verified experimentally. This is confirmed theoretically by the use of the Neyman-Pearson lemma which makes it possible to formally determine the statistical tests with the best performances. These results also make it possible to understand the paradox of the possible divergence of the detection limit. It is also formally shown that the confidence intervals thus calculated by getting rid of the nuisance parameter according to established methods result in the commonly used confidence interval. To our knowledge, this constitutes the first formal derivation of these confidence intervals.This method is based on keeping the measurement results whether they are significant or not (not censoring them). This is recommended in several standards or documents, is compatible with the ISO 11929 standard and is in line with recent proposals in the field of statistics. On the other hand, all the information necessary to determine whether a measurement result is significant or not remains available. The conservation and restitution of all results is currently applied in the USA. The textbook case of the WIPP incident makes it possible to ensure favorable public perception.The implications and applications of this method in different fields are finally discussed.

Explore related subjects

Keep this discovery

BibTeXRIS

Guillaume Manificat, Salima Helali, Patrick Bouisset. 2024-03-01. Classical and Bayesian statistical methods for low-level metrology. https://arxiv.org/abs/2403.00385

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det