PCH-EM: A solution to information loss in the photon transfer method

Abstract

Working from a Poisson-Gaussian noise model, a multi-sample extension of the Photon Counting Histogram Expectation Maximization (PCH-EM) algorithm is derived as a general-purpose alternative to the Photon Transfer (PT) method. This algorithm is derived from the same model, requires the same experimental data, and estimates the same sensor performance parameters as the time-tested PT method, all while obtaining lower uncertainty estimates. It is shown that as read noise becomes large, multiple data samples are necessary to capture enough information about the parameters of a device under test, justifying the need for a multi-sample extension. An estimation procedure is devised consisting of initial PT characterization followed by repeated iteration of PCH-EM to demonstrate the improvement in estimate uncertainty achievable with PCH-EM; particularly in the regime of Deep Sub-Electron Read Noise (DSERN). A statistical argument based on the information theoretic concept of sufficiency is formulated to explain how PT data reduction procedures discard information contained in raw sensor data, thus explaining why the proposed algorithm is able to obtain lower uncertainty estimates of key sensor performance parameters such as read noise and conversion gain. Experimental data captured from a CMOS quanta image sensor with DSERN is then used to demonstrate the algorithm's usage and validate the underlying theory and statistical model. In support of the reproducible research effort, the code associated with this work can be obtained on the MathWorks File Exchange (Hendrickson et al., 2024).

Explore related subjects

Keep this discovery

BibTeXRIS

Aaron J. Hendrickson, David P. Haefner, Stanley H. Chan, Nicholas R. Shade, Eric R. Fossum. 2024-03-07. PCH-EM: A solution to information loss in the photon transfer method. https://arxiv.org/abs/2403.04498

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det