SearcharxivSearch

arXiv · 2403.05880

A molecular dynamics simulation of the abrupt changes in the thermodynamic properties of water after formation of nano-bubbles / nano-cavities induced by passage of charged particles

Abstract

We present a multi-scale formalism that accounts for the formation of nano-scale bubbles/cavities owing to a burst of water molecules after the passage of high energy charged particles that leads to the formation of hot non-ionizing excitations or thermal spikes (TS). We demonstrate the coexistence of a rapidly growing condensed state of water and a hot spot that forms a stable state of diluted water at high temperatures and pressures, possibly at a supercritical phase. Depending on the temperature of TS, the thin shell of a highly dense state of water grows by three to five times the speed of sound in water, forming a thin layer of shock wave (SW) buffer, wrapping around the nano-scale cylindrical symmetric cavity. The stability of the cavity, as a result of the incompressibility of water at ambient conditions and the surface tension, allows the transition of supersonic SW to a subsonic contact discontinuity and dissipation to thermo-acoustic sound waves. We further study the mergers of nanobubbles that lead to fountain-like or jet-flow structures at the collision interface. We introduce a time delay in the nucleation of nano-bubbles, a novel mechanism, responsible for the growth and stability of much larger or even micro-bubbles, possibly relevant to FLASH ultra-high dose rate (UHDR). The current study is potentially significant at FLASH-UHDRs. Our analysis predicts the black-body radiation from the transient supercritical state of water localized in nano-cavities wrapping around the track of charged particles can be manifested in the (indirect) water luminescence spectrum.

Explore related subjects

Keep this discovery

BibTeXRIS

Ramin Abolfath, Niayesh Afshordi, Sohrab Rahvar, Adri van Duin, Martin Radler, Reza Taleei, Katia Parodi, Julie Lascaud, Radhe Mohan. 2024-03-09. A molecular dynamics simulation of the abrupt changes in the thermodynamic properties of water after formation of nano-bubbles / nano-cavities induced by passage of charged particles. https://doi.org/10.1140/epjd%2Fs10053-024-00928-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph